2. Click on the "Control Output" button to open the Control Output window. Select "LED 1" from the
Output drop down, enter 500 for Duty, and enter 1000 for Period as shown in Figure 43. This will
command ema:Play to control it's LED 1 (ref des D18) to flash at a frequency of ~2 Hz.
Figure 43
3. Click the "Control Output" button to close this window. Click the "Control Output" confirmation
button to send the command as shown in Figure 44.
Figure 44
At this point the Canopy servers will post the command data for retrieval by the next ema:Play
Leaf request. This can take up to 10 seconds. Observe on the ema:Play hardware that the RED LED
D18 is flashing.