Kaba LA GARD COMBOGARDPRO Manager's Manual

Kaba LA GARD COMBOGARDPRO Manager's Manual

Dual-handed swingbolt or deadbolt lock

Advertisement

Quick Links

Lock Choices
Dual-Handed Swingbolt
STANDARD FEATURES
Manager Mode
• Open Lock
• Activate/Delete Users
• Enable/Disable Users
• Set Time Delay Values
User Code
• Open Lock
• Change Code
Wrong Try Penalty
• Four (4) consecutive invalid codes initiates five minute
delay period.
Low Battery Warning
• Repeated audio and visual signal (LED flashing and
repeated beeping) during opening indicates battery low.
Audio and Visual Signal
• Double signal (LED flashes and unit beeps) indicates entry
is valid or accepted.
• Triple signal indicates invalid or not accepted.
Audit Trail
• On board non volatile memory records up to 63 last
events, including user ID and action.
PROGRAMMABLE FEATURES
Code length
(from 6 to 9 digits)
Multiple Users
1
2
3
4
5
6
Time Delay
• Delay period 1 - 99 minutes
• Open period 1 - 19 minutes
Time Delay Override
• Ability to add second combination to override delay period
Dual Code
• Two codes required to open
Silent Signal Alarm (Optional Alarm Box Required)
• Duress signal if last number of code(s) is entered using
one number higher or one number lower.
Signal to Disable Lock Opening
(Optional Alarm Box Required)
• Input signal disables opening of lock by valid code
Signal to Disable Lock (Optional Alarm Box Required)
• Input signal disables all lock functions by valid code
© copyright 2008
Dual-Handed Swingbolt or Deadbolt Lock Instructions
Suggested Keypad
Deadbolt
Round Entry
______________
7
8
9
______________
______________
(P/N) 732.018 (Manager)
MANAGER GUIDE
• All locks are shipped from the factory in Pre
Set-up mode, with no features installed.
• Lock will open when 1 is pressed.
• Please follow ComboGard Pro setup
instructions (P/N 731.018) to initially configure
locks settings.
3750-K
OPENING THE LOCK
1. Enter valid Manager or User code.
2. The unit will indicate a valid code entry with a
double signal.
3. Within four (4) seconds open lock by either rotating
the keypad to open position (clock-wise) or turning
the handle to the open position.
4. Pull door open.
• Invalid Code Entry - Unit will signal three (3) times.
CHANGING CODE
ALWAYS PERFORM THIS OPERATION WITH THE
DOOR OPEN
Each code must be changed independently.
1. Enter existing code and hold down the last digit
until unit double signals twice and the LED
stays on.
2. Press the "0" key.
3. Enter your NEW code, then re-enter NEW code
to confirm.
4. If a mistake is made wait thirty (30) seconds and
repeat steps 1 - 3.
5. Test unit operation several times before closing
the door.
• Valid Code Entry - Double signal after valid code
ACTIVE
is entered.
• Invalid Code Entry - Triple signal and old code
is still valid.
ACTIVATING USER
ALWAYS PERFORM THIS OPERATION WITH THE
DOOR OPEN
1. Enter Manager code and hold down last digit of
code until unit double signals twice and the LED
stays on.
2.
PRESS 1. Unit signals twice.
3. Press User number, 1 to 9. Unit signals twice.
4. Enter NEW code, then re-enter NEW code
to confirm.
5. If a mistake is made wait thirty (30) seconds and
repeat steps 1 - 4.
• Valid Code Entry - Double signal after valid code
is entered.
• Invalid Code Entry - Triple signal and old code is
still valid.
LA GARD - A Member of the Kaba Group
Page 1 of 3

Advertisement

loading

Summary of Contents for Kaba LA GARD COMBOGARDPRO

  • Page 1 • Invalid Code Entry - Triple signal and old code is Signal to Disable Lock (Optional Alarm Box Required) • Input signal disables all lock functions by valid code still valid. LA GARD - A Member of the Kaba Group © copyright 2008 (P/N) 732.018 (Manager) Page 1 of 3...
  • Page 2 3. Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on. 4. PRESS 7. Unit signals once and Audit will be sent. 5. Disconnect Interface Cable from PC and keypad. LA GARD - A Member of the Kaba Group © copyright 2008 (P/N) 732.018 (Manager)
  • Page 3 4002 Large Battery/Alarm Box battery compartment. 6. Replace the cover and test the unit several times before closing the door LA GARD - A Member of the Kaba Group © copyright 2008 (P/N) 732.018 (Manager) Page 3 of 3...