Dual-handed swingbolt or deadbolt lock

Advertisement

DISABLE USER
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on.
2. PRESS 2. Unit signals twice.
3. Press User number, 1 to 9. Unit signals once.
4. User is temporarily disabled.
5. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
• Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
REINSTATE USER
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on.
2. PRESS 1. Unit signals twice.
3. Press User number, 1 to 9. Unit signals once.
4. User is reinstated.
5. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
• Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
DELETE USER
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on.
2. PRESS 3. Unit signals twice.
3. Press User number, 1 to 9. Unit signals once.
4. User is deleted.
5. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
• Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
CHECK USER STATUS
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on.
2. PRESS AND HOLD DOWN 7. Unit signals twice.
3. Press User number, 1 to 9.
4. Unit will signal once is the user is active, twice is the user is disabled, three times if the User is available. The unit
will signal with one extended signal is the User is unavailable.
5. To exit PRESS 0.
SET/CHANGE TIME DELAY VALUES
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on.
2. PRESS 9. Unit signals twice.
3. Enter Delay period value, from 00 to 99 minutes. For example five (5) minutes would be entered by pressing the 0
key and then the 5 key.
4. Enter Open period value, from 00 to 19 minutes. For example two (2) minutes would be entered by pressing the 0
key and then the 2 key. Unit will signal twice.
Note: Selecting 0000 minutes deactivates the Time Delay Feature.
5. Confirm all four values. Unit signals twice and feature is active.
NOTE: If Time Delay is active it may only be deactivated or delay value decreased in Open Period.
RECEIVE AUDIT
This function requires Serial Interface (P/N 43087) and LGVIEW Software
1. Plug Interface into PC and open LGView 3X software on PC.
2. Connect Interface to front of keypad and click safe icon button on the PC software to begin acquisition.
3. Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on.
4. PRESS 7. Unit signals once and Audit will be sent.
5. Disconnect Interface Cable from PC and keypad.