Download Print this page
Breas NIPPY Clearway Patient Manual
Hide thumbs Also See for NIPPY Clearway:

Advertisement

Quick Links

A Patient Guide to
the NIPPY Clearway
NIPPY
®
Clearway

Advertisement

loading
Need help?

Need help?

Do you have a question about the NIPPY Clearway and is the answer not in the manual?

Questions and answers

Summary of Contents for Breas NIPPY Clearway

  • Page 1 A Patient Guide to the NIPPY Clearway NIPPY ® Clearway...
  • Page 2 Your device will be set up by your physiotherapist/clinician. The NIPPY Clearway gives a deep breath in (insufflation) followed by a rapid suck out (exsufflation). This simulates what naturally happens when you cough and therefore can make your cough stronger...
  • Page 3 Navigation of your NIPPY Clearway Outlet Mask Pressure On/Off – Press once to turn device on, press twice to turn device off Air Outlet – Attach Insufflation/Exsufflation Trigger (for use Mask Pressure Line Valve large tubing here in manual mode) – Move the switch to –...
  • Page 4 Navigation of your NIPPY Clearway Hand control – for use External Battery – in manual mode Twist clockwise to Mains power Air inlet filter lock in place connection and cover...
  • Page 5 Setting up your NIPPY Clearway Interface options Tubing Place the NIPPY Clearway on a clean, smooth, hard surface (not carpet). Pressure monitoring line Connect to the mains or battery. Carbon dioxide leak port. Attach the breathing circuit to the air outlet and pressure line to the Do not cover this up during mask pressure valve on the front of the NIPPY Clearway.
  • Page 6 • If possible, try to avoid treatment immediately after a meal or food. • When using the NIPPY Clearway in the automatic modes, a Synchrony Beep will sound prior to the delivery of the negative pressure, signalling when to cough (if mucus is present), making the treatment more effective.
  • Page 7: Starting Treatment

    Starting treatment Changing the mode on your NIPPY Clearway When you switch on the NIPPY Clearway, it will remember the last settings that were used, so you will not The NIPPY Clearway has 5 different modes. need to set up the device each time, unless you are changing to a different prescription or mode.
  • Page 8: Cleaning And Maintenance

    Cycle Pause provided by Breas Medical Ltd or reputable The number in the top right corner shows • Using a clean, damp cloth, wipe down distributor. Push the filter cover back in place...
  • Page 9: Troubleshooting

    Your prescription settings 1 Your NIPPY Clearway device will alarm or display a message when it requires attention. Below is a list of common alarms or information messages and what to do if these occur while you are using the device.
  • Page 10 Your prescription settings 2 Your prescription settings 3 Mode Mode Insufflation Pressure Exsufflation Pressure Insufflation Pressure Exsufflation Pressure Insufflation Trigger Insufflation Trigger Cycle Repeat Cycle Repeat Pause Device locked Yes/No Pause Device locked Yes/No Insufflation Repeat Interface Insufflation Repeat Interface Advance Settings: Advance Settings: Insufflation Oscillations...
  • Page 11 Notes Notes...
  • Page 12 *NIPPY Clearway is a trademark of Breas Medical AB © 2017 Breas Medical – All rights reserved. Breas Medical reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation.