Download Print this page
Aeotec ZWA005 Manual

Aeotec ZWA005 Manual

Trisensor

Advertisement

Quick Links

Used in this guide.
Important safety information.
Please read this and the electronic guide(s) at
to follow the recommendations set forth by Aeotec Limited may be dangerous or cause a violation of
the law. The manufacturer, importer, distributor, and / or reseller will not be held responsible for any
loss or damage resulting from not following any instructions in this guide or in other materials.
TriSensor is intended for use in dry locations only. Do not use in damp, moist, and / or wet locations.
Contains small parts; keep away from children.
Quick start.
The following will step you through installing TriSensor and connecting it to your Z-Wave network.
1. Select an installation location for TriSensor. The sensor uses light and heat readings to detect
motion, so avoid pointing it at sources of both. Tips on optimising the installation location of
TriSensor can be found online in its digital guide.
2. Remove the backplate from TriSensor.
3. Insert one CR123A batteries with the correct orientation.
4. Replace the backplate.
5. Set your Z-Wave gateway into its 'add device' mode in order to connect TriSensor to your Z-
Wave system. Refer to the gateway's manual if you are unsure of how to perform this step.
6. inclusion in network:
Press once TriSensor's Action Button,If it is the first installation., the yellow LED will keep
solid until whole network processing is complete. If successful, the LED will flash white -> green ->
white -> green ,After 2 seconds have finished.If fail, the yellow LED lasts for 30 seconds, then the
green LED flashes once.
If it is the S2 encryption network, please enter the first 5 digits of DSK, and the location of
DSK is shown in the figure1.
7. exclusion out network:
Press once TriSensor's Action Button, the Purple LED will keep solid until whole network
processing is complete.if the exclusion is successful, the LED will flash white -> green ->white ->
TriSensor
ZWA005
http://support.aeotec.com/trisensor
carefully. The failure

Advertisement

loading

Summary of Contents for Aeotec ZWA005

  • Page 1 The failure to follow the recommendations set forth by Aeotec Limited may be dangerous or cause a violation of the law. The manufacturer, importer, distributor, and / or reseller will not be held responsible for any loss or damage resulting from not following any instructions in this guide or in other materials.
  • Page 2 To see if this device is known to be compatible with your Z-Wave gateway, please refer to http://aeotec.com/z-wave-gateways Declaration of Conformity. Aeotec Limited declares that TriSensor is in compliance with the essential requirements and other relevant provisions of RED 2014/53/EU, RoHS 2011/65/EU, IEC62321:2008 and EN50581:2012. Command Class Configuration...
  • Page 3 Motion Retrigger Time This parameter is configured the delay time before PIR sensor can be triggered again to reset motion timeout counter. Value = 0 will disable PIR sensor from triggering until motion timeout has finished. Parameter Number Size (Byte) Available Settings Default value 0 ~ 32767...
  • Page 4 Basic Set Value Settings for Group 2 ‘0’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0x00 to devices associated in group 2 when motion event is cleared. ‘1’– Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0xFF to devices associated in group 2 when motion event is cleared.
  • Page 5 Led Color For Temperature Sensor Report ‘0’ – Disable. ‘1’ – Red. ‘2’ –Green. ‘3’ – Blue. ‘4’ – Yellow. ‘5’ – Pink. ‘6’ – Cyan. ‘7’ – Purple. ‘8’ – Orange. Parameter Number Size (Byte) Available Settings Default value 0 ~ 8 Led Color For Light Sensor Report ‘0’...
  • Page 6 ‘3’ – Blue. ‘4’ – Yellow. ‘5’ – Pink. ‘6’ – Cyan. ‘7’ – Purple. ‘8’ – Orange. Parameter Number Size (Byte) Available Settings Default value 0 ~ 8 Temperature Scale Setting Configure temperature sensor scale type, Temperature to report in Celsius or Fahrenheit. 0 –...
  • Page 7 Temperature Offset Value The current measuring temperature value can be add and minus a value by this setting. The scale can be decided by Parameter Number 20. Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit) Parameter Number Size (Byte) Available Settings Default value -200 ~ 200...
  • Page 8 COMMAND_CLASS_SENSOR_MULTILEVEL (V7) COMMAND_CLASS_CONFIGURATION (V1) COMMAND_CLASS_SUPERVISION (V1) The full text of the declaration is available from https://support.aeotec.com/trisensor/doc Specifications.Z-Wave devices operate between 868.40 & 926.30 MHz depending on local restrictions. It uses up to -0.36dBm ERP transmit power, enabling long range connectivity. Full information on device specifications and certifications at support.aeotec.com/trisensor/specs...