Vionic Readhead Installation Drawing - Renishaw VIONiC RESM20 Installation Manual

Angle encoder system
Table of Contents

Advertisement

VIONiC readhead installation drawing

(RESM20 'A' section ring shown)
Optical centreline (incremental and
R > 30 Dynamic bend radius
R > 10 Static bend radius
4.6
*  Extent of mounting face.
NOTE: External magnetic fields greater than 6 mT, in the vicinity of the readhead, may cause false activation of the limit and reference sensors.
VIONiC RESM20/REST20 angle encoder system
reference mark)
'A' section – Offset 1.75 ±0.5
18
'B' section – Offset 3.25 ±0.5
29
6 min
35
23
11.5
(Yaw tol. ±0.4°)
0.25
Forward direction of ring
(increasing count)
Set-up LED
2 mounting holes M2.5 through, counterbored Ø3 × 2.3 deep both sides.
NOTE: The recommended thread engagement is 5 min (7.5 including counterbore)
and the recommended tightening torque is between 0.25 and 0.4 Nm.
(Pitch tol. ±1°)
Rideheight: 2.1 ±0.15
Dimensions and tolerances in mm
(Roll tol. ±0.5°)
0.08
Mounting faces
13.5
4.25
4.15
0.6
8.75 *
10
4