Operator Specifications

Usage Classification
Main AC Supply
System Operating Voltage
Accessory Power
Solar Power Max
Maximum Gate Weight/Length
90 Degree Travel Time
Maximum Travel Range
Maximum Daily Cycle Rate
Maximum Duty Cycle
Operating Temperature
External Entrapment Protection Device Inputs
(non-contact and/or contact)
27.85" (70.7 cm)
16.77" (42.6 cm)
INTRODUCTION
Class I, II, III, & IV
120 Vac, 4 Amps (10 Amps including Accessory Outlets) OR 240 Vac, 2 Amps
When Optional Transformer Kit Model 3PHCONV is installed in the field, operator is rated
208/240/480/575 VAC, 5.2/4.5/2.3/1.9 A, 60 Hz, 1 PH
24 Vdc Transformer Run / Battery Backup
24 Vdc, 1A max. for ON + SW (switched)
24 Vdc at 60 watts max.
14 ft. - 2,800 lbs.
16 ft. - 2,400 lbs.
To optimize performance and extend operator life, the long arm kit model HDLGARM is
recommended when installing with gates 16 ft. or longer. See Accessories
When HDLGARM is used, operator has the following maximum gate weight/length:
14 ft. - 4,500 lbs.
16 ft. - 3,750 lbs.
13-36 seconds NOTE: Travel time will vary based on arm configuration and speed control settings.
115 degrees NOTE: Travel range will very based on arm configuration.
Continuous
Continuous
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
Main board - up to 2 close entrapment protection devices and 1 open entrapment protection device.
Expansion board - up to 3 entrapment protection devices configurable to either the close or open
direction and up to 8 edge sensors when using the wireless edge sensor kit model LMWEKITU and
LMWETXU.
1.31" (3.3 cm)
14.82" (37.6 cm)
8
18 ft. - 2,200 lbs.
20 ft. - 1,800 lbs.
18 ft. - 3,250 lbs.
20 ft. - 2,750 lbs.
12.2" (31 cm)
14" (35.6 cm)
22 ft. - 1,500 lbs.
page
53.
22 ft. - 2,500 lbs.