Chamberlain HDSW24UL Installation Manual page 50

Commercial dc vehicular swing gate operator
Hide thumbs Also See for HDSW24UL:
Table of Contents

Advertisement

Wire the Solar Panels and Batteries
24W min. - 60W max. for solar applications.
NOTE: 33AH batteries are strongly recommended for optimal solar
performance.
1. Connect (+) wire from solar panels to (+) pin on CHARGE IN
connector on control board.
2. Connect (-) wire from solar panels to (-) pin on CHARGE IN
connector on Control board.
3. Set the WALL XFMR/SOLAR switch to SOLAR.
20W APPLICATION IN SERIES
10W
SOLAR PANELS
Red Wire
Red wire from
battery harness
33AH, HD Gates
K41-0102-000
33AH Batteries
Set Switch to SOLAR
Control Board
40W APPLICATION IN SERIES
10W
10W
10W
Jumper
Black Wire
Black wire
from battery
harness 33AH,
HD Gates
K41-0102-000
10W
20W
20W
10W
50
Red Wire
Jumper
Black Wire
7AH Batteries
Battery Wiring
60W APPLICATION IN SERIES
10W
10W
20W
10W
10W
10W
10W
20W
10W
10W

Advertisement

Table of Contents
loading

Table of Contents