Operator Specifications
Usage Classification
Main AC Supply
System Operating Voltage
Accessory Power
Solar Power Max
Maximum Gate Weight
Minimum Gate Travel Distance
Maximum Gate Travel Distance
Maximum Gate Travel Speed
Maximum Daily Cycle Rate
Maximum Duty Cycle
Operating Temperature
Expansion Board
External Entrapment Protection Device Inputs (non-contact
and/or contact)
INTRODUCTION
Class I & II
120 Vac, .5 Amps (6.5 Amps including Accessory Outlets)
12 Vdc Battery Run / Battery Backup
12 Vdc, 500mA max. for ON + SW (switched)
12 Vdc at 30 watts max.
800 lbs (363.6 kg)
25 feet (7.62 m)
50 feet (15.24 m)
12 inches/second
120 cycles/day
Continuous
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
Optional
Main board - up to 2 close entrapment protection devices and 1 open entrapment
protection device.
Expansion board - up to 3 entrapment protection devices configurable to either close or
open and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU .
7