Configuration
(DMX)
DMX Personality
and Starting
Address

Master/Slave

Mode

Scorpion Bar RG User Manual Rev. 1.1
Set the product in DMX mode to control with a DMX controller. The product uses 3-pin DMX
cable.
1.
Connect the product to a suitable power outlet.
2.
Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket
on the product.
When selecting a DMX starting address, always consider the number of DMX channels used by
the fixture. If you choose a starting address that is too high, you could restrict the access to
some of the product's channels.
The Scorpion Bar RG uses up to 10 DMX channels in the 10-channel mode, 10H, which means
the highest recommended DMX address for that personality is 503.
The Scorpion Bar RG uses 2 DMX channels in the 2-channel mode, 2 H, which means the
highest recommended DMX address for that personality is 511.
If you are not familiar with the DMX protocol, download the DMX Primer from
http://www.chauvetlighting.com.
To select the DMX personality and starting address, do the following:
1.
Press <MENU> repeatedly until 2 H or 10H will show in the display
2.
Press <ENTER> and 001–512 shows on the display.
3.
Use <UP> or <DOWN> to select the DMX address.
4.
Press <ENTER> and 001–511 (for 2H) or 001–503 (for 10H) will show on the display.
The display will continue to blink until the fixture receives a DMX signal.
The Master/Slave mode allows a single Scorpion Bar RG product (the master) to control the
actions of one or more Scorpion Bar RG products (the slaves) without the need of a DMX
controller. The master will be set to operate in either Automatic or Sound-Active mode, while the
slaves will be set to operate in Slave mode. Once set and connected, the slave units will operate
in unison with the master.
Configure the products as indicated below.
For every slave:
1.
Set the product's DMX address to 001.
· Configure all the slave units before connecting the master to the DMX daisy chain.
· The display on the slaves will continue to blink until the slaves are receiving a DMX
signal from the master.
For the master:
1.
Connect the DMX output of the master to the DMX input of the first slave unit.
2.
Set the master unit to operate in either Automatic or Sound-Active mode
· Make sure the master is the first unit in the DMX chain.
· Never connect a DMX controller to a DMX chain configured for Master/Slave operation
because the controller may interfere with the signals from the master.
· Do not connect more than 31 slaves to the master.