Bosch CAM 847 Initial Start-Up page 23

Tester set for unit injectors and unit pumps
Hide thumbs Also See for CAM 847:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
9. Connect the additional UI/UP PCB to the trigger
electronics using the supplied ribbon cables (x3).
Fig. 4:
Attaching the ribbon cables
10. Remove both covers (see Fig. 1, Pos. 6 and 7) from
the housing. The covers are no longer needed.
11. Install the two supplied connectors in the housing
with the code facing upwards.
X 5
X 6
X 7
X 8
X 9
X 1 0
Fig. 5:
Inserting the connectors
Robert Bosch GmbH
Structure | CAM 847 | 23
12. Carefully push the trigger PCB (Fig. 6, Pos. 3) onto
the spacers in the housing.
3
Fig. 6:
Installing the trigger PCB
13. Fasten the trigger PCB using the fastening screw
(Fig. 1, Pos. 4) and washer (Fig. 1, Pos. 5).
14. Plug all connecting cables into the PCB.
15. Connect all cables to the additional UI/UP PCB.
X 1
X 2
X 3
X 4
X 5
Fig. 7:
Plugging in the connectors
16. Put on the cover.
17. Secure the cover once more with the self-tapping
screws.
X 6
X 7
X 8
X 9
X 1 0
|
1 689 978 508
2011-12-03
en

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents