TROUBLESHOOTING

The Plasmacluster Ion
Generator does not work.
How often should I do cleaning
and maintenance?
Cleanliness Monitor color
does not change. Odor Monitor
does not light up.
The Cleanliness Monitor stays
yellow and does not turn
green. The Odor Monitor stays
yellow and does not turn off.
The Cleanliness Monitor
display switches frequently.
The unit display is too bright.
The Cleanliness Monitor does
not light up.
FP-JC2.indd
20
Problem
WHAT TO DO
• Is the Car Adapter connected properly?
Ensure it isconnected correctly.
• Does not a fuse blow?
Replace with a new fuse.
• Does the car use a 24V battery?
The air purifier is not compatible with 24V batteries.
• To maintain ion concentration and air purifying
performance, clean the pre-filter about once
a month.Regular and careful cleaning helps
maintain ion release and dust collection performance.
• When the unit has been running it for some time,
sensor sensitivity sometimes becomes unstable
and Cleanliness Monitor color does not change as a result.
• When the Cleanliness Monitor color remains
green (the Odor Monitor is not lit), the air
is being kept clean.When blowing cigarette
smoke and the like on the sensor cover causes
the Cleanliness Monitor to change color, the
Cleanliness Monitor is working properly.
• Inserting the car adapter into the accessory
socket and starting to drive when there is a very
strong odor in the car can lower dust and odor
sensor sensitivity.In this case, remove the car
adapter from the power input terminal, ventilate
the car, and then reinsert the car adapter into the
power input terminal and begin driving.
• Is the air purifier installed in a place where it
is difficult to detect dirt? Is the dust and odor
sensor cover and filter dirty?Install the air purifier
in a different place and clean the sensor.
• Adjust sensor sensitivity.
• Is a car window or door open?
When outdoor air is entering the vehicle it may
take time until the Cleanliness Monitor turns green.
• Dirty or clogged dust(sensitive) sensor openings
interfere with sensor operation. Gently clean the
sensor filter or the sensor cover.
• This could be a response to wind due to opening
and closing doors.
• Adjust sensor sensitivity.
• The Cleanliness Monitor, Odor Monitor, and Filter
maintenance lamp can be turned off.Press the
lamp Brighter, Darker, Turn Off button to switch
the brightness level. (See E-00)
• Is the lamp set to the Turn Off setting?
• Press the lamp Brighter, Darker, Turn Off button
to switch the brightness. (See E-00)