End User Relay Command Mode When Using The 4286 Vip Module - ADEMCO 4286 VIP Installation And Setup Manual

Vista interactive phone module
Hide thumbs Also See for 4286 VIP:
Table of Contents

Advertisement

4286 VIP Module Installation and Setup Guide
End User Relay Command Mode When
Using the 4286 VIP Module
For information on whether operation of the end-user Relay Command mode
via the telephone is possible with the control being used, refer to the control's
Installation Instructions and the following.
Voice feedback is possible only with certain controls.
The following is a summary of the different methods available for manual op-
eration of relays and/or power line carrier devices via the phone in various
Ademco systems. These end user functions are discussed in the 4286 VIP
Module User's Guide.
VISTA 10, VIA-30P
These control panels can use non-voice response relay commands to
manually turn devices on or off. However, field *80 (Output Relay pro-
gramming) must include
System Operation choices 34 (Code + # + 7) and/or 35 (Code + # + 8) for
ZT (Zone Type/System Operation) for a selected relay.
When so programmed, the relay for which System Operation choice 34 or
35 was selected can be manually activated or de-activated by keying:
Code + # + 7 or Code + # + 8.
VISTA 20 (all controls)
This control panel uses non-voice response relay commands to manually
turn devices on or off, as follows:
4-digit system code + # + 7 + device No. will turn on the device.
4-digit system code + # + 8 + device No. will turn off the device.
The above mentioned controls will NOT provide voice feedback and there will
be no voice confirmation over the phone that the command has been exe-
cuted. However, wired keypads in the security system will "beep" for confir-
mation.
VISTA 40, VISTA 50P
These control panels use the interactive "# 70 Relay Command Mode" to
manually turn devices on or off.
4-6