Do NOT connect speakers in parallel.
Do NOT use a single 4-ohm speaker.
Damage to the 4286 may result.

Special Wiring Notes:

1. Wire the 4286 VIP Module exactly as indicated in Table 2-1 and on the
Summary of Connections diagram on the inside back cover of this man-
ual, unless the control's installation instructions indicate otherwise (due,
for example, to the use of other phone-connected devices such as an Audio
Alarm Verification unit).
2. You MUST make a connection to the incoming Telco line via an RJ31X
jack (CA38A in Canada) and direct-connect cord, as shown in the Sum-
mary of Connections diagram, even if the system is not connected to a
central station. The 4286 will not operate properly if this is not
done.
3. If Touch-tones are not present following access to the security system via
an on-premises phone, try reversing the pair of wires connected to termi-
nals 3 & 4 on the 4286 VIP Module, and the pair of wires connected to the
"Handset" TIP & RING terminals on the control.
4. Connect a Caller ID unit to the security system as you would an answer-
ing machine and other phones.
4286 VIP Module Terminal
1. Phone In (Tip)
2. Phone In (Ring)
3. Phone Out (Tip)
4. Phone Out (Ring)
5. Not Connected
6. Audio Out
7. Audio Out
Section 2. Mounting and Wiring

Table 2-1. Wiring Connections

"Handset" TIP terminal on control
"Handset" RING terminal on control
BROWN lead from direct-connect cord
GRAY lead from direct-connect cord
Not Connected
One side of speaker
One side of speaker
Connects to: