5. Vessel Makes Noise or Leaking
Verify vessel mounting
Step 5A
Verify whether vessel is secured to pad. If not,
secure vessel to pad. If secured, go to step 5B.
Inspect quartz sleeve
Step 5C
Inspect the quartz sleeve for damage. If damaged,
replace (HYX2DQSA). If not, go to 5D.
38
Inspect top vessel o-ring
Step 5B
Turn off pump, and inspect top vessel o-ring. If
damaged, replace (SB2KIT). If Ok go to step 5C.
Inspect drain plug
Step 5D
With pump off, inspect drain plug & o-ring. If
damaged, replace (BSX1PLUG2).