2. Power LED Not Lit (cont.)
CAUTION: Transformer output is 240VAC!
Transformer output
Transformer input
Step 2D
Step 2E
Verify Transformer output is 192-288VAC. If OK
Verify Transformer input is 108-132VAC between
replace PCB (GLX-HYDPCB). If NO/LOW go to 2E.
pins 1-3 & 2-4. If OK replace transformer (GLX-
HYDXFMR), if NO/LOW replace PCB (GLX-HYDPCB).