2. Power LED Not Lit
Verify source power
Verify LED power
Step 2A
Step 2B
Verify source power (108-132VAC). If NO/LOW
Test for 10 - 12VDC on LED input. If NO/LOW go to
resolve incoming power. If correct go to 2B.
step 2C, if OK contact support: 908.355.7995.
Check PCB fuses
Step 2C
Remove fuses and verify continuity. If open,
replace fuse(s), if closed go to step 2D.