Cleaning The Quartz Sleeve: Manually (cont.)
8. Remove the stainless steel sleeve from the top seal plate before moving on (Fig. 29 & 30).
9. Remove quartz sleeve by turning the locknut counter clockwise and removing (Fig. 31 & 32).
Carefully clean both the inside and the outside of the quartz sleeve using NON-ABRASIVE
CLEANERS, as they can scratch the high quality glass. If lime or hard water calcium deposits are
encountered, rinse the quartz sleeve with tap water, then clean with lime removal products
such as Lime-A-Way® using lint-free cloth. After using the lime removal products, rinse and wipe
with alcohol. Completely dry the sleeve both inside and out before placing the UV lamp inside
the quartz sleeve.
10. Carefully inspect the cleaned quartz sleeve for cracks. If any cracks in the quartz sleeve are
found, the sleeve should be replaced. Broken quartz sleeve will allow water to enter the dry
electrical chamber and attack the electrical components of the unit, which will cause them to
fail.
Fig. 29
23
Fig. 30
Fig. 31
Fig. 32