Cleaning The Quartz Sleeve: Manually (cont.)
6. Use a soft clean cotton cloth (or cotton gloves)
to remove the lamp(s) by grasping the lamp
connector and rotating counter-clockwise to
unlock the lamp from the nut (Fig. 27).
7. Once unlocked, slowly pull the lamp straight
up and away from the quartz sleeve until it
clears the vessel (Fig. 28). Carefully place the
lamp(s) in a safe location while cleaning the
quartz sleeve.
CAUTION: The UV lamp is sensitive to
handling and should be allowed to fully
cool before being moved. Wait at least 30
minutes after disconnecting power to
begin the removal process.
NOTE: If you should touch the lamp with
your bare hands, it can be cleaned with a
soft cotton cloth and rubbing alcohol
22
Fig. 27
Fig. 28