Hayward HydroRite UVO3 Troubleshooting Manual page 24

Uv ozone system
Hide thumbs Also See for HydroRite UVO3:
Table of Contents

Advertisement

Cleaning The Quartz Sleeve: Manually (cont.)
11. Slowly lower the lamp down into the quartz sleeve (Fig. 33). Once sleeve is secured (Fig. 34),
reconnect the 4-Pin Connector to the pins on top of the lamp.
NOTE: DO NOT touch the lamp with bare hands (Use included gloves). The ceramic 4-Pin
Connector is designed to fit onto the end of the lamp in ONLY ONE ORIENTATION. Clean
and re-lubricate the O-ring before reinstalling the enclosure cover.
12. Gently clean the UV Sensor using a non-abrasive cleaning solution and a soft cloth.
13. Place the plastic electrical cover on the top of the HydroRite unit and tighten the screws using a
Phillips head screwdriver (Fig. 35).
14. Plug in the power cord. Turn on the circulation pump, making sure to open any valves (if
applicable). Verify that the lamp is lit.
15. HydroRite should now be operational!
Fig. 33
24
Fig. 34
Fig. 35