Display Indicators; Factory Defaults - Vogelzang International VG130 Owner’s Instruction And Operation Manual

Table of Contents

Advertisement

TROUBLE SHOOTING
Error Code
The high limit temperature sensor has
Err1
tripped.
Stove ran out of fuel during normal
Err2
operation.
The stove was unable to reach the Room
Err3
Fan On temperature within the start-up
time.
The power failed while the stove was hot,
Err4
and when power was restored, the fire was
out.
Err5
The Auger output fuse has blown.
Err6
The Ignitor output fuse has blown.
The Draft Fan (Exhaust Fan) output fuse
Err7
has blown.
Err8
The Room Fan output fuse has blown.

DISPLAY INDICATORS

Several situations or events are indicated in normal
operation by blinking display indicators or segments in the
display:
Flashing On - This means that the stove is in the "Start
Up" state waiting for the ignition procedure to complete.
Flashing Off - This indicates that the stove is in the
"Shut Down" state waiting for the off button, or for a 15
minute period after the stove was turned off, or for the
stove to cool down, or for the door to be closed.
Flashing dash in Heat Range Display - This
indicates that the stove is in the normal run mode and is
ramping from the current heat range setting to the target
heat range setting. Once the ramp is complete, the dash
will stop flashing. For ramping from heat range 1 to 5, the
default time is 12 minutes (with a 90 second ramp time).
Flashing Automatic Mode - This indicates that the
stove is in normal operation and is running in the automatic
mode. However, either the draft fan or room fan setting is
manually configured.
Error Description
Possible Causes
Inadequate ventilation.
Room fan failure.
Exhaust Blockage.
Electrical Open in wiring.
Hopper Empty.
Auger output failure or jam.
Flame of fuel quality caused fire to burn too slowly or go
out.
Electrical Open in wiring.
The high limit thermosdisc has tripped and will need to be
manually reset.
Flame or Fuel quality caused the fire to burn too slowly or
go out.
Auger output failure or jam Hopper empty on start-up.
Electrical Open in wiring.
Power loss
Auger motor jammed or bad.
Ignitor shorted out or bad.
Draft Fan motor jammed or bad.
Room fan motor jammed or bad.
Flashing Draft Fan Setting - This indicates that the
stove is in normal operation and that the vacuum sensor
detects a loss of pressure either because the door is open
or because there is a negative pressure in the room with
respect to the exhaust.
Flashing Aux - This indicates that the ignitor is on
during the lighting stage.
Quickly (changes twice per second) Flashing
Heat Range Setting - This indicates that the stove is in
normal operation and that an over-temperature condition
exists causing the fuel to stop.
Slowly (changes once per second) Flashing
Heat Range Setting - This indicates that the stove is
in a cut back condition in an attempt to prevent an over-
temperature shut down.

FACTORY DEFAULTS

To return the control to its original factory default settings,
press and hold the AUX UP and AUX DOWN buttons
together for three seconds.