Configuring The Heating System; Parameters For Heating - Bosch FB 100 Installation And Operating Instructions Manual

Remote control and room sensor for fw 200 on a boiler with heatronic 3
Hide thumbs Also See for FB 100:
Table of Contents

Advertisement

US/CA
8.2

Configuring the heating system

Installer settings: System configuration
For menu structure and adjustment ranges
page 32.
For system examples, see the
instructions for the IPM. Other
examples can be found in the
planning documents.
Use this menu if you want to configure the system
automatically or manually. E.g. on commissioning
the system for the first time or making changes to
it.
B Set ID of all BUS devices according to their
function (e.g. IPM2 for heating circuit 1 and
heating circuit 2, etc.).
B Start automatic configuration.
B Check the other menu options under System
configuration and, if necessary, adjust
manually to suit the present system.
Menu settings INSTALLER SETTINGS (for installers only) | 35
8.3
Installer settings: Heating parameters
For menu structure and adjustment ranges
page 33.
Use this menu if you want to set the parameters
for the assigned heating circuit. For example, the
heating curves can be calculated with these
parameters.
Menu: Heating parameters > Heating circuit
type
B Set the heating type of the assigned heating
circuit:
– Baseline/Design temp: Default settings for
– Radiant Floor: Default settings are used
– Radiators: Default settings are used for a
– Baseboard: Default settings are used for a

Parameters for heating

Set the supply temperature control
on the boiler to the maximum
required supply temperature.
a level heating curve are used according to
the classic base point/end point method.
for a sloped heating curve as in a radiant
floor heating circuit.
sloped heating curve as in a radiator
heating circuit.
sloped heating curve as in a convector
heating circuit.
Parameters not used in a particular
type of heating are not shown.
6 720 643 259 (2010/05)