28 | MAIN MENU settings
If, for example, the programming for
Thursday differs from the other
weekdays, the options All days and
Mon - Fri show ----- from --:-- for all
settings. I.e. there are no common
switch points and operating modes
for this selection.
B Reset heating program to factory settings
page 21.
B Change name of heating program using
and
. The 18 characters displayed can be
individually replaced by selecting the letters
and numbers offered.
To enter spaces:
B When the selected character is
shown with a dark background,
delete by pressing
(space = _ )
Menu: Heating > Program > View
B Shows switch points and associated
operating modes for All days, Mon - Fri, Sat +
Sun or the individual day of the week as a
segment pattern.
6.3.2 Temperature for the operating modes
and heat-up rate
Menu: Heating > Parameter
Use this menu to permanently set the
temperature levels for the 3 operating modes
(Comfort
/ Economy
heating rate to suit your personal preferences
and your home.
6 720 643 259 (2010/05)
/ Frost
) and the
Menu: Heating > Parameter > Heating levels
B Setting the desired room temperature for the
operating modes:
– Comfort
= maximum desired
temperature (e.g. when the living space is
occupied and occupants require a
comfortable room temperature).
– Economy
= medium desired
temperature (e.g. when a lower
temperature is sufficient or when the home
is empty or everyone is in bed and you do
not want the house to cool down too
much).
– Frost
= minimum desired temperature
(e.g. when the home is empty or everyone
is in bed and it is OK for the house to cool
down). Consider any pets and plants.
Menu: Heating > Parameter > Heat-up speed
B Setting the desired heat-up speed for the
Heating circuit:
– Economy = The building is heated up
slowly, thus saving energy.
– Normal = The building is heated up at the
"normal" rate.
– Fast = The building is heated up quickly,
thus providing maximum comfort.
6.4

DHW

The FB 100 has no settings for a DHW program,
program for the recirculation pump, parameters
for DHW and thermal disinfection for a DHW tank.
These settings must be made on the outdoor
reset control.
The DHW heating can be activated on the FB 100
with a brief press of the
(
section 5.1.3 on page 17).
US/CA
button

Advertisement