Airstream INTER 2V4SA User Manual page 14

Table of Contents

Advertisement

INTER 2V4SA
II.  Activating the Ramp
• If you have just finished specifying ramp
steps, press the Other Functions button once
again. The word OFF flashes on the display.
• Press the up-arrow adjustment button.
The word ON  flashes on the display and
the Temperature Ramp status LED flashes,
indicating that the temperature ramp is now
activated.
or
• If you have previously defined ramp steps,
select the SET  POINT/TEMP  RAMP  menu
and then press the Other Functions button
to scroll down all ramp steps, until the word
OFF appears (twenty-one clicks).
• Press the up-arrow adjustment button.
The word ON  flashes on the display and
the Temperature Ramp status LED flashes,
indicating that the temperature ramp is now
activated.
III.  Adjusting the Day Number
The day number can be adjusted in order
to move forward or backward on the ramps
(temperature and min. ventilation ramp).
• Select the CURRENT RAMPING DAY menu.
The current day number is displayed, alternat-
ing with the letters "day".
• Use the adjustment buttons to set it to the
desired value.
14
INTER 2V4SA, rev.02
IV.  Deactivating  the  Temperature 
Ramp
• Select the SET POINT/TEMP RAMP menu
and then press the Other Functions button
to scroll down all ramp steps, until the word
ON appears (twenty-one clicks).
• Press the down-arrow adjustment button
once. The word OFF flashes on the display
and the Temperature Ramp status LED turns
off.

Advertisement