Factory Settings - Airstream INTER 2V4SA User Manual

Table of Contents

Advertisement

INTER 2V4SA
15. 
Factory Settings
PARAMETER
Temperature Set Point
Outside T° Alarm Offset
Stage 1
Minimum Speed
Time On
Time Off
Bandwidth
Override Min
Speed
Humidity
Humidity Set Point
Control
Compensation
Percentage
Stage 2
Offset
Bandwidth
Min. Speed
De-icing
Cycle Time
De-icing Time
Stages 3-6
Differential
Mist
Time On
Time Off
Offset
Differential
Mist Shut off
humidity level
Heater
Heater Offset
Max. Temperature
Diff. Btwn Zones
Alarms
High Offset
Low Offset
i) These initial parameter settings will not be re-
tained in the controller's memory. Each new setting
will replace the preceding one.
ii) If the power supply is cut off, the last parameter
settings will be retained in memory until the power
is restored.
FACTORY 
SETTING
25,0°C (77,0°F)
-40,0 to 48,9°C
(-40,0 to 120,0°F)
1,0°C (1,8°F)
0,3 to 20,0°C
(0,5 to 36,0°F)
40%
10 % to 100 %
0 seconds
0 to 900 seconds in increments of 15 sec.
15 seconds
1,0°C (1,8°F)
0,3 to 10,0°C
(0,5 to 18,0°F)
40%
10 to 100%
65%
40 to 100%
60%
0 to 100% of stage 1 min speed
0,3°C (0,5°F)
From set point to 10,0°C (18,0°F)
1,0°C (1,8°F)
0,3 to 10,0°C (0,5 to 18,0°F)
40%
10 % to 100 %
1 minute
1 to 720 minutes
15 seconds
15 to 900 seconds
1,0°C (1,8°F)
0,3 to 10,0°C (0,5 to 18,0°F)
60 seconds
0 to 900 sec. in increments of 15 sec.
10 minutes
0 to 720 minutes
4,0°C (7,2°F)
0,3 to 20,0°C (0,5 to 36,0°F)
1,0°C (1,8°F)
0,3 to 10,0°C (0,5 to 18,0°F)
95%
0 to 100%
1,0°C (1,8°F)
-5,0 to 10,0°C (-9,0 to 18,0°F)
4,0°C (7,2°F)
0,3 to 20,0°C (0,5 to 36,0°F)
7,0°C (12,6°F)
0,3 to 20,0°C (0,5 to 36,0°F)
5,0°C (9,0°F)
0,3 to 20,0°C (0,5 to 36,0°F)
RANGE 
OF VALUES
INTER 2V4SA, rev.02
37