INTER 2V4SA
6. 
Temperature Settings
6.1. 
Temperature Units
To select the desired measuring units used
to display temperatures, set internal switch
# 2 to the desired position:
ON: to display temperatures in
Celsius units.
OFF: to display temperatures in
Fahrenheit units.
6.2. 
Viewing Temperatures
I.  Viewing the Room Temperature
The room temperature is the average value
of all temperatures measured by activated
probes in proper operating condition.
• Select the ROOM TEMP MIN / MAX menu.
The average room temperature is displayed.
II.  Viewing Probe Temperatures
The controller can display probe temperatures
individually. Probes can also be turned on or
off to control the temperature in different
parts of the building.
• Select the PROBE  TEMP  /  MIN  /  MAX 
menu. The temperature reading of probe 1
is displayed, alternating with letters "Pr 1"
and the on/off state of the probe.
• Press the Other Functions button. The let-
ters "Pr 1" are displayed, alternating with the
temperature reading from probe 1 and the on/
off state of the probe.
• For each additional probe, Other Functions
button. The letters "Pr x" are displayed, al-
ternating with the temperature reading from
probe x and the on/off state of the probe.
III.  Viewing  Minimum  /  Maximum 
Temperatures
Follow this procedure to see the lowest and
highest room temperature values that have
been recorded since the last reset.
• Select the ROOM TEMP MIN / MAX menu.
The average room temperature is displayed.
ON
OFF
2
• Press the up-arrow adjustment button. The
maximum temperature is displayed, alternat-
ing with the letters "Hi".
ON
OFF
2
• Press the down-arrow adjustment button.
The average temperature is displayed. Press
the down-arrow adjustment button once
again.
The minimum temperature is dis-
played, alternating with the letters "Lo".
NOTE: If you let the display flash for more
than 10 seconds, the controller resets the min
and max temperatures currently in memory
to the current average room temperature. To
avoid resetting these values, return to the
average temperature display using the adjust-
ment button (up-arrow or down-arrow) before
the 10 second delay has elapsed.
IV.  Viewing  Min/Max  Probe  Tem-
peratures
Follow this procedure to see the lowest and
highest temperature readings that have been
recorded by each probe since the last reset.
• Select the PROBE  TEMP  /  MIN  /  MAX 
menu. The temperature reading of probe 1 is
displayed, alternating with the letters "Pr 1"
and the on/off state of the probe.
• Press the up-arrow adjustment button. The
maximum temperature of probe1 is displayed,
alternating with the letters "Pr1 Hi".
• Press the down-arrow adjustment button.
The current temperature of probe 1 is dis-
played once again.
INTER 2V4SA, rev.02