• Use the adjustment buttons to set the On
Time to the desired value (in minutes).
• Press the Other Functions button The cur-
rent Off Time for the mist cycle is displayed,
alternating with the letters "t Off".
• Use the adjustment buttons to set the Off
Time to the desired value (in minutes).
IV.  Adjusting the Mist Shutoff Limit
The mist shutoff set point is the humidity
level over which mist units stop running. This
parameter is only displayed if mist units are
enabled (internal switch #9) and if less then
2 heaters are used. The mist shutoff value
ranges from 0 to 100% of humidity. Select
"No" if you want to disable this function.
• Select the MIST  RH  COMPENSATION 
menu. The humidity level over which mist
units turn off is displayed, alternating with
the letters "rH OFF".
• Use the adjustment buttons to set it to the
desired value.
27
INTER 2V4SA, rev.02