5.2. ELECTRICAL CONNECTION (Fig. 4A-4B).
Connection to the power supply must be carried out in
compliance with the regulations and provisions in force in the
country of use.
ATTENTION!
Work on the electrical systems must only be
carried out by a qualified electrician.
Before carrying out any cleaning or maintenance
operation, disconnect the appliance from the
power supply and carefully unplug it.
IMPOR- TANT! Before connecting make sure:
- the mains voltage and frequency match that given on the
dataplate and that there is an efficient earth contact.
- the system power supply is arranged and
able to take the actual current absorption and that it is
correctly executed according to the regulations in force in
the country of use;
- a differential thermal-magnetic switch suitable for the input
specified on the dataplate, with contact gap enabling complete
disconnection in category III overvoltage conditions and
complying with the regulations in force, is installed between
the power cable and the electric line. For the correct size of
the switch, refer to the absorbed current specified on the
appliance dataplate.
- the mains voltage and frequency match that given on the
dataplate.
• To access terminal block, remove the front panel of the
appliance by removing the fixing screws;
• Connect the power cable to the terminal block as shown in
the wiring diagram attached to the appliance.
• Secure the power cable with the cable gland.
IMPORTANT! The manufacturer declines any liability if the
safety regulations are not respected.
• After making the connection, with the machine working
check that the power supply does not fluctuate by ±10% the
rated voltage.
• Installation requires the inclusion of a device lockable in the
"open" position during maintenance
5.2.1.
POWER CABLE
Unless otherwise specified, our appliances are not equip-
ped with a power cable. The installer must use a flexible
cable having characteristics at least equivalent to H05RN-F
rubber-insulated type. Protect the cable section outside the
appliance with a metal or rigid plastic pipe.
If the power cable is damaged, it must be replaced by the
after-sales service or in any case by qualified personnel,
in order prevent any risk.
The manufacturer declines any liability for damage or
injury resulting from breach of the above rules or non-
compliance with the electrical safety regulations in force
in the country where the machine is used.
5.3. EQUIPOTENTIAL NODE AND EARTH CONNECTION
Connect the appliance to an earth; it must be included in
an equipotential node by means of the screw located at the
front right under the frame. The screw is marked with the
symbol
.
6. WATER CONNECTION
ATTENTION!
The water connection must be carried out by a specialised
technician.
The appliance must be supplied with drinking water at a
pressure of 1.5 - 3 bar.
Attention! If the water pressure is higher than that specified,
use a pressure reducer to avoid damaging the appliance.
For correct installation, the water inlet pipe must be connected
to the mains by means of a mechanical filter and a shutoff
cock. Before connecting the filter, allow a certain amount of
water to flow in order to clear the pipe of any waste matter.

7. SAFETY THERMOSTAT

Some of our appliance models use a safety thermostat that
cuts in automatically when temperatures exceed a set value,
shutting off the gas supply (gas appliances) or the electricity
(electric appliances).
7.1 INTERVENTION
With braisers, intervention of the limiter indicates an incorrect
use or an appliance malfunction; resetting must be carried
out by a specialised technician when the appliance is cold.
IMPORTANT: Tampering with the safety thermostat invali-
dates the warranty
8. BEFORE COMPLETING INSTALLATION
OPERATIONS
Use soapy water to check all gas connections for leaks. DO NOT
use a naked flame to check for gas leaks. Light all the burners
separately and also together, to check correct operation of
the gas valves, rings and lighting. For each burner, adjust the
flame regulator to the lowest setting, individually and together;
after completing the operations, the installer must instruct the
user on the correct method of use. If the appliance does not
work properly after carrying out all the checks, contact the
local after-sales service centre.