Electrically driven piston pump units for single-line centralized lubrication systems (44 pages)
Summary of Contents for SKF Linkoln Pile Driver III C Series
Page 1
User and maintenance instructions Pile Driver III pump assembly Models 2328, 2356, 84923, series “C” Date of issue February 2018 Form number 404395 Version...
Contents Explanation of Safety safety signals • Read and carefully observe operating instructions before unpacking and Explanation of safety signals ..operating pump. Pump must be operated, NOTE Safety ......maintained and repaired exclusively by Emphasizes useful hints and Gland packing design .
Gland packing Specifications design Pump stroke 6 in (152 mm) Output per cycle 85 in (1 393 cm Operating temperature –30 to +160 °F (–34 to +71 °C) Recommended speed max. 75 cycles/min Many industrial type materials (sealants, Output at 75 cycles/minute 27.6 gal/min (104,5 l/min) adhesives, inks, etc.) display a tendency to Wetted part materials...
Operation NOTE WARNING precautions Install pump in upright position. Do not exceed stated maximum working Use model 83727 stand pipe for bulk pressure of pump or of lowest rated material dispensing. component in system. Locate pump as close to tank as possible Do not alter or modify any part with minimum 3 in (76 mm) ID inlet hose of equipment.
Pump prime Disassembly 6 Remove pump tube (15) from outlet body (13). 7 Remove O-ring (14) from To begin operation, pump has to be primed Standard tools required are: outlet body (13). with pumped material. Pile Driver III pump is in wrench (30) 8 Remove bleeder valve (12) from...
Page 7
Fig. IPB 1 Torque to 100–120 lbf-ft (136–163 Nm). Torque to 120–150 lbf-ft (163–204 Nm). Assemble to (17) with #242 Loctite. Torque to 24–26 lbf-ft (33–35 Nm). Install wipers (5) and U-cups (8, 23) in direction shown in enlarged views.
Troubleshooting Condition Possible cause Corrective action Pump does not operate. Restricted or inadequate air supply. Check air supply pressure and air hose diameter for minimum air supply hose diameter. Obstructed material output. Check output line for restrictions. Pump speeds up or runs erratically. Pump is not primed.
Need help?
Do you have a question about the Linkoln Pile Driver III C Series and is the answer not in the manual?
Questions and answers