Download Print this page
Welbilt MULTIPLEX BIC MA-8-2 Service Bulletin
Welbilt MULTIPLEX BIC MA-8-2 Service Bulletin

Welbilt MULTIPLEX BIC MA-8-2 Service Bulletin

3 amp breaker tripping
Hide thumbs Also See for MULTIPLEX BIC MA-8-2:

Advertisement

Quick Links

Service Bulletin
SYMPTOM
3 AMP breaker located on back of BIC Manual Fill continually tripping from overload.
TROUBLESHOOTING
WARNING
n
TO AVOID SHOCK OR DAMAGE TO UNIT
DISCONNECT THE POWER SUPPLY!
,
SHARP BLADES AND EDGES. WEAR PPE
(GLOVES AND GOGGLES) TO PREVENT INJURY.
NOTE: Breaker version may vary. (See Figure 1)
1. Check unit is:
• On a dedicated breaker.
• Plugged into a dedicated outlet.
• NOT plugged into a GFI outlet.
• Has correct voltage to shaver motor (See Figure 2)
With a voltage meter set for DC voltage, insert
your leads into the black and white wires with
the connector still connected. Go into the
manager's menu, service and then outputs.
Arrow down to shaver motor and turn on the
shaver motor. You will then be able to read the
voltage at the connector. You should have 120
volts DC +/- 10%.
2. Check the ice shaver blade for cracks, chips, and/or dull
edges. (See Figure 3)
NOTE: If ice shaver blade has unused side it can be
uninstalled, rotated 180 degrees and reinstalled to keep
machine operating. New blade will need to be ordered and
installed promptly.
3. Check the ice shaver blade screws to make sure they
are not backing out. (See Figure 4)
CAUTION
Subject: 3 Amp Breaker Tripping
SCOPE: ALL MULTIPLEX MODEL MA-8-2 BIC MANUAL FILL
Document Number: MPX-154
2100 FUTURE DR, SELLERSBURG, IN 47172
WWW.MULTIPLEXBEVERAGE.COM
3 AMP Breaker
Push Button
Rocker Switch
FIGURE 1 - Breaker Location and Versions
FIGURE 2 - Check Shaver Motor Voltage
BAD
GOOD
FIGURE 3 - Ice Shaver Blade
FIGURE 4 - Ice Shave Blade Screws
MULTIPLEX
844-724-CARE
BACK VIEW
1 of 2
July 26, 2019

Advertisement

loading

Summary of Contents for Welbilt MULTIPLEX BIC MA-8-2

  • Page 1 MULTIPLEX 2100 FUTURE DR, SELLERSBURG, IN 47172 844-724-CARE WWW.MULTIPLEXBEVERAGE.COM Service Bulletin Subject: 3 Amp Breaker Tripping SCOPE: ALL MULTIPLEX MODEL MA-8-2 BIC MANUAL FILL SYMPTOM 3 AMP breaker located on back of BIC Manual Fill continually tripping from overload. 3 AMP Breaker TROUBLESHOOTING WARNING TO AVOID SHOCK OR DAMAGE TO UNIT...
  • Page 2 8. Check the pillow block shaft in the ice bin to make sure it is mounted firmly (not moving back and forth or side to side). (See Figure 9) FURTHER ACTIONS Contact Welbilt KitchenCare if you have any questions or concerns: 1-844-724-CARE (2273). FIGURE 9 - Pillow Block Shaft 2 of 2...