7.0 TROUBLESHOOTING

7.1 LOW WATER LEVEL
Proper water level must be maintained within the jacket for the kettle to operate.
Depletion of water may occur from excessive opening of or leakage through the safety
relief valve.
If water is below required operating level, either initially at start-up or during use, the
kettle will automatically shut off and the LOW WATER signal light will come on.
In order for the kettle to operate, the following procedure must be followed:
The kettle must be cool before proceeding with the following steps.
1. Trip the safety relief valve lever to relieve all pressure from the kettle jacket.
2. At exterior rear of kettle jacket remove nut from Air Vent.
3. Insert funnel into Air Vent opening and slowly add the indicated amount of clean
water for:
CAPACITY
20 gallon kettle
30 gallon kettle
40 gallon kettle
60 gallon kettle
80 gallon kettle
100 gallon kettle
4. Replace air vent nut.
5. Follow AIR VENTING INSTRUCTIONS below.
6. Continue normal operating procedure of kettle.
ADD:
140 ounces
4.14 litres
150 ounces
4.44 litres
220 ounces
6.50 litres
250 ounces
7.39 litres
340 ounces
10.05 litres
420 ounces
12.42 litres
15
IF COMPLETELY EMPTY, ADD:
376 ounces
11.12 litres
504 ounces
14.90 litres
548 ounces
16.20 litres
586 ounces
17.33 litres
850 ounces
25.12 litres
1088 ounces
32.17 litres