Service Connections - Blodgett KCH-30DS Installation Operation & Maintenance

Kch-ds series direct steam cabinet base tilting kettle
Hide thumbs Also See for KCH-30DS:
Table of Contents

Advertisement

1.0 SERVICE CONNECTIONS

ELECTRICAL CONNECTION: (Tilt models only) 1/2" conduit connection to controls. Unless otherwise specified, Field Wire Electrical Connection to be 120
Volts, 60 Hertz single phase 10 Amps with grounding wire.
DRAIN: 5/8 O.D. tubing to open floor drain. No Solid Connection.
STEAM SUPPLY: 3/4" IPS for incoming steam. Min 5 PSI(34 kPa), MAX 30 PSI(207 kPa), 45 PSI (310 kPa) optional.
S
Important: Pressure reducing valve required if incoming steam pressure exceeds the kettle rating.
COLD WATER: 3/8" O.D. Tubing to faucet.
HOT WATER: 3/8" O.D. tubing to faucet.
MODEL
CAPACITY
UNITS
3O gallons
inches
KCH-30DS
114 litres
mm
40 gallons
inches
KCH-40DS
151 litres
mm
60 gallons
inches
KCH-60DS
227 litres
mm
B
ØA
S
3.25 [83]
6 [152]
S
18.5 [470]
SEE NOTE
S
DIMENSIONS
A
B
24
36
610
914
26
36
660
914
29.5
42
749
1067
DIMENSIONS ARE IN INCHES [MM].
3.25 [83]
S
NOTE: Area for kettle draw off
must be kept free of all piping connections.
C
D
16
39
37.25
406
991
946
15
40
38.38
381
1016
975
16
43
41.12
406
1092
1045
C
D
4
E
F
G
41.5
65.25
1054
1657
42.5
68.25
1080
1733
47.62
74.25
1210
1886
FLANGED FOOT DETAIL
2
EQUALLY SPACED
Ø
7/16" [11mm] HOLES
ON 2.5 [63] B.C.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kch-40dsKch-60ds

Table of Contents