2.0 SERVICE CONNECTIONS

MODEL
KLT-12G
Ø20 [508]
Ø16.75 [425]
I.D.
30 [762]
SERVICE CONNECTIONS
Unless otherwise specified, Field Wire Electrical Connection to be 120
Volts, 60 Hz. single phase with grounding wire. Unit furnished with 6'
cord and 3 prong plug. Total max. amps 2.0.
GAS CONNECTION: Supply gas through 3/4" pipe.
NATURAL 6" - 14" W.C. (152mm - 355mm W.C.)
PROPANE 12" - 14" W.C. (305mm - 355mm W.C.)
Contact manufacturer for installation over 2,000 ft. elevation.
3 [76]
4.75 [121]
DIMENSIONS ARE IN INCHES [MM]
FLANGED FOOT DETAIL
4
EQUALLY SPACED
Ø
7/16" [11mm] HOLES
ON 3 [76] B.C.
POUR PATH
11.25 [286]
15 [381]
4
BTU/HR.
kW/HR.
43,000
12.6
6 [152]
MIN.
17.25 [438]
7.75 [197]