Installation Instructions - Blodgett KCH-30DS Installation Operation & Maintenance

Kch-ds series direct steam cabinet base tilting kettle
Hide thumbs Also See for KCH-30DS:
Table of Contents

Advertisement

2.0

INSTALLATION INSTRUCTIONS

WARNING: Electrical and grounding connections must comply with
applicable portions of the National Electrical Codes.
WARNING: Plumbing connections must comply with applicable health,
safety and plumbing codes.
1. Select a location to provide drainage directly below the draw-off valve. Allow
sufficient rear clearance from the wall for the kettle cover to lift upright freely without
obstructions. Allow for clearance to side service panels.
2. Level the unit. Then mark anchoring hole locations through flanged adjustable feet.
3. With hole locations marked, drill holes and insert expansion plugs to accommodate
5/16" size lag bolts.
4. Reposition the kettle. Check the level again.
5. Bolt the kettle down and seal with a high grade sealing compound. Sealant must be
applied not only to bolt heads but around the flanges and must be making contact
with floor surface to meet N.S.F. requirements. Wipe off excess sealant
immediately.
6. Connect the steam line to the kettle (3/4" i.p.s., 5 psi minimum to 30 psi maximum, or
45 psi with optional high pressure operation).
7. If the incoming steam pressure is greater than the kettle maximum operating
pressure, then a pressure reducing valve (supplied by others) must be installed in
the line.
8. Connect hot and cold water supply to the faucet.