Service Connections - Blodgett KLT-40GS Installation Operation & Maintenance

Short height gas tilting kettle
Table of Contents

Advertisement

Service Connections

SERVICE CONNECTIONS
Gas Connection - Supply gas through 3/4" pipe . A gas
G
shut-off valve must be installed in supply piping convenient
and adjacent to appliance.
Electrical Connection - Unless other wise specified,
EC
Field Wire Electrical Connection to be 120 Volts, 60 Hertz
single phase with grounding wire. Unit furnished with 8'
cord and 3 prong plug. Total max. amps 4.0.
Hot Water Connection - 3/8" tubing to faucet (OP-
HW
TIONAL)
Hot Water Connection - 3/8" tubing to faucet (OP-
CW
TIONAL)
DIMENSIONS ARE IN INCHES [MM]
14.75
[375]
22.5 [572]
38.5
[978]
17.25 [438]
INSTALLATION
51 [1295]
3.63 [92]
G
EC
2 [51]
H
18.75
POWER
ON
COOKING
LOW WATER
[476]
COOK TEMP.
OFF
PRESSURE
200
300
400
G
100
TUBE AND CONNECTION
316 SS
500
0
600
kPa
psi
WATER LEVEL
6.38
[162]
INSTALLATION CLEARANCE
Left Side
0" [0mm]
„ BTU/Hour: 125,000
„ kW/Hour: 36.63
„ Gas Supply (Supply Pipe Pressure W.C.)
‰ Natural 6"-14" (152-356mm)
‰ Propane 11"-14" (279-356mm)
* Use on non-combustible floors only.
C
* Shown with option faucet, cover and draw-off.
52.25
[1327]
74.5
[1892]
37.75
36 [914]
[959]
Figure 1
2
Right Side
0" [0mm]
REAR FLANGED FOOT DETAIL
2 EQUALLY SPACED
Ø7/16" [11mm] HOLES
ON 2.5" [63mm] B.C.
A
4 [102]
MINIMUM
EC
G
8.5 [216]
H
C
Rear
4" [102mm]
33.5 [891]
21