Dometic SI 600 acs User Manual
Dometic SI 600 acs User Manual

Dometic SI 600 acs User Manual

Pure sine wave inverter

Advertisement

Quick Links

SI 600 acs – 12V/24V
Pure Sine Wave Inverter
230Vac
12Vdc / 24Vdc source
from
acs
Integrated automatic 230Vac transfer switch -
User's Manual / Benutzerhandbuch / Manuel de l' utilisateur
Användarhandbok / Manuale d' uso / Manual del usuario

Advertisement

Table of Contents
loading

Summary of Contents for Dometic SI 600 acs

  • Page 1 SI 600 acs – 12V/24V Pure Sine Wave Inverter 230Vac 12Vdc / 24Vdc source from Integrated automatic 230Vac transfer switch - User’s Manual / Benutzerhandbuch / Manuel de l' utilisateur Användarhandbok / Manuale d' uso / Manual del usuario...
  • Page 2 Vdc source. Once the AC utility is restored, the relay is energized and the load is automatically reconnected to the AC utility. You have made a wonderful choice to use Inverters from Dometic. Feel free to contact our dealers for more information or other recommendations within mobile power supply.
  • Page 3: Table Of Contents

    5.2 System Status LEDs..............14 Information..................15 6.1 Troubleshooting ................15 Maintenance ................16 6.3 Warranty ..................16 © Copyright: This manual is the copyright of DOMETIC and may not be reproduced or copied without the express permission of the owner.
  • Page 4: Important Safety Instructions

    Important Safety Instructions WARNING ! Before you install and use your Dometic SI 600acs Inverter, be sure to read these safety instructions. General Safety Precautions 1-1-1. Do not expose the SI 600acs inverter to rain, snow, spray, bilge or dust.
  • Page 5: Basic Descriptions

    Basic Descriptions Mechanical drawings...
  • Page 6: The Front Panel Interface

    The Front panel interface 2-2-1. Power ON / OFF / REMOTE switch:If you use the optional remote control unit, put the “on/off “ switch to “remote”. 2-2-2. 230Vac input Circuit Breaker:The 7Amp circuit breaker protects the model from overload. When an overload condition exists, the circuit breaker stops output AC grid power.
  • Page 7: The Rear Panel Interface

    The rear panel interface 2-3-1. Ventilation: Do not obstruct, allow at least 2-3 inches/ 50-75mm of clearance for airflow. 2-3-2. 230V AC input: (source) If available and desired, plug into 230Vac source directly.
  • Page 8: The Remote Control Panel

    The Remote Control panel Inverter Status Solid Red Inverting Blinking R.O.F Acting Blinking Ignition PUSH ON/OFF The Remote control is a basic ON/ OFF remote control. The control has features which disable and override the ON/OFF function such as: Ignition Lockout function This will automatically turn the Inverter OFF when the auxiliary input wiring receives a continuous 12V/24V signal.
  • Page 9: Functional Characteristics

    Functional Characteristics General Information The SI 600acs Inverter is designed as a stand –alone power inverter with an AC transfer switch feature which is suitable for RV, marine and emergency appliances. When utility AC power is cut off, the transfer relay is de-energized and the load is automatically transferred to the SI 600acs output.
  • Page 10: Features

    Features Product: 600W continuous output with 800W power surge for electronic appliances. Pure sine wave output (THD < 3%) to operate higher-end electronic equipment. Built in 7A rating AC transfer switch with plug-in socket that is easy to maintain. Speed up transfer time and synchronized operation with the AC source at all times which allows the transfer to be interruption-free for sensitive equipment.
  • Page 11: Electrical Performance

    Electrical Performance Specification Model No. Item SI600acs 24V SI600acs 12V Continuous Output Power 600W Maximum Output Power (3Min.) 680W Surge Rating 800W Input Voltage 230V Output Voltage / Frequency 50Hz +/- 0.05% Efficiency (full load) 90.0% No Load Current Draw 0.43A 0.87A Output Waveform...
  • Page 12: Installation

    Installation Where to install The power inverter should be installed in a location that meets the following requirements: 4-1-1. Dry – Do not allow water to drip or splash on the inverter. 4-1-2. Cool – Ambient air temperature. 4-1-3. Safety – Do not install batteries in a compartment or other areas where flammable fumes existence such as fuel storage areas or engine compartments.
  • Page 13: Ac Safety Grounding

    AC Safety Grounding During the AC wiring installation, AC input and output grounding should be present in the connection with the inverter. The AC input grounding must connect to the incoming grounding of your AC utility sources and the AC output grounding should connect to the grounding point for your loads (for example, a distribution panel ground bus).
  • Page 14: Making Dc Wiring Connections

    Code (NEC) to protect the battery and cables, A UL listed DC rated slow blow fuse must be installed in line with the positive battery cable, within 18 inches/ 0.5m of the battery. DOMETIC recommends the following cables for an optimum inverter performance. Model No...
  • Page 15 WARNING ! The installation of an inline fuse must be on positive cable. Failure to place a fuse on “+” cables running between the Inverter and battery may cause damage to the inverter and will void warranty.
  • Page 16: Operation

    Operation To operate the SI 600acs Inverter, turn it on by using the ON/OFF/REMOTE switch. The inverter is now ready to deliver AC power to your loads. If you are loading several appliances, turn them on separately after the inverter is switched on; this process is to avoid delivering all the starting currents at once to all the loads.
  • Page 17: System Status Leds

    System Status LEDs. There are 3 LED indicators located on the front panel of the inverter. Input Level, Load Level, and Power status. 1. Input Level: Displays Input Voltage LED Status DC 12V DC 24V Red Blink (slow) 10.5~10.9 21.0~21.8 10.9~11.3 21.8~22.6 Orange...
  • Page 18: Information

    Information Troubleshooting WARNING ! Do not open or disassemble the SI 600acs Inverter. Attempting to service the unit may result in a risk, electrical shock or fire. Problems and Possible Cause Solutions Symptoms No output voltage, the LED glows RED light. a.
  • Page 19: Maintenance

    We warrant this product against defects in materials and workmanship for a period of 12 months from the date of purchase and will repair or replace any defective Dometic Inverter when directly returned, postage paid, to us. This warranty will be considered void if the unit has suffered any obvious physical damage or alteration either internally or externally.
  • Page 20 Further Information about Dometic products www.dometic.com...

Table of Contents