Description of the product

General description

®
The MARTIN
MultiPort Air Cannon Controller, hereinafter referred to as
controller, serve to control a maximum of one MARTIN
Cannon. The work cycle of the MARTIN
be triggered by a programmable time control, an external impulse or manu-
ally.

Control and display elements

FAULT
Red
AUTOMATIC
Green
MAN. AUTO
1
0
I
I
Figure 1: Control and display elements
1.
The green signal lamp (1) indicates that the system is working in au-
tomatic mode.
2.
The operation mode selector switch (2) is used to adjust the desired
operation mode:
• „MAN" - semiautomatic mode. In semiautomatic mode, a port is
selected with the slave selector switch (3) and it is triggered
according to the programming of the selected port.
• „0" - MultiPort Controller is switched off. No air cannons are
being triggered.
• „AUTO" - automatic mode. The ports are triggered in accordance
with a programmed time sequence.
3.
The port selector switch (3) serves to preselect the ports for semiauto-
matic operation.
4.
The main switch (4) puts the controller into operation or switches it
off and serves simultaneously as an emergency switch in the event of
a malfunction.
®
MultiPort Air Cannon can either
RUN
Air Tank Full
White
Yellow
7
5
6
2
3
8
®
MultiPort Air
4
I ON
0
OFF