Martin M3776UK Operator's Manual

Multiport controller

Advertisement

Quick Links

®
MARTIN
MultiPort
Controller
Operators Manual
M3776UK

Advertisement

Table of Contents
loading

Summary of Contents for Martin M3776UK

  • Page 1 ® MARTIN MultiPort Controller Operators Manual M3776UK...
  • Page 2: Table Of Contents

    Connection diagram..............12 Programme sequence..............13 Controller operator device............14 Selection of the parameter ............14 Changing parameter..............14 Operational controls cabinet............18 ® MARTIN MultiPort air cannon controller ......... 22 Terminal connections diagram ............. 24 © Martin Engineering GmbH M3776UK-05/10...
  • Page 3: Introduction

    „Intended use“. Entitlement to damages is generally excluded, unless wilful intent or gross negligence on the part of Martin Engineering GmbH is proven, or if promi- sed product features are missing. We are not responsible for the possible consequences if the product is used in environments for which it is not sui- table or which do not comply with the technical standard.
  • Page 4 In the event that malfunctions and/or technical problems occur, please speak to the service department at Martin Engineering GmbH. We guaran- tee to implement suitable measures immediately. The guarantee provisions of Martin Engineering GmbH apply; we will gladly send these to you on request. 1.1.4...
  • Page 5: Safety Instructions, Safety At Work

    Safety instructions, safety at work These operating instructions must be read through in full before starting ® work on the MARTIN MultiPort Controller. The operator must ensure that all assembly, inspection and maintenance work is carried out by authorised and qualified members of staff who have kept themselves adequately informed by thoroughly studying the operating instructions.
  • Page 6: Symbols In These Instructions

    Dangerous and unsafe procedures! Dangerous and unsafe procedures, which can result in damage to the product or property. IMPORTANT Important instructions for the proper installation and the correct operation of the devices. NOTE General, useful instructions. © Martin Engineering GmbH M3776UK-05/10...
  • Page 7: References

    Issue 2002-05 • DIN/EN 60204-1 „Safety of machinery - Electrical equipment of machinery, Part 1 General requirements“, Issue 1998-11 • MOELLER operating instructions „easy800“ control relay - AWB2528-1423D - 06/03 © Martin Engineering GmbH M3776UK-05/10...
  • Page 8: Description Of The Product

    Description of the product General description ® The MARTIN MultiPort Air Cannon Controller, hereinafter referred to as controller, serve to control a maximum of one MARTIN ® MultiPort Air ® Cannon. The work cycle of the MARTIN MultiPort Air Cannon can either be triggered by a programmable time control, an external impulse or manu- ally.
  • Page 9: Serial And Model Number

    The serial and model numbers are stated on the type plate which is attached to the upper right of the switch cabinet. Please state these numbers when ordering spare parts at Martin Engineering or an authorised dealer, as well as in all correspondence.
  • Page 10: Before Installation

    • MARTIN ® MultiPort Air Cannon Controller • possibly additional parts according to the order. If anything is missing contact Martin Engineering or the relevant rep- resentative. WARNING Before installing, turn off energy source to air cannon and all air cannon accessories.
  • Page 11: Installing Controller

    Figure 3: Dimensions of the controller NOTE ® Mounting at a different location than directly to the MARTIN MultiPort air cannon is not envisaged. If you want to install the control system at a different location, please observe the mass stated in fig. 3 and all valid standards and regulations with regard to the installation and use of electrical equipment.
  • Page 12: Connection Of The Controller

    Lay all lines from and to the control system in such a way that a risk of stumbling is excluded and the lines are protected from damage. © Martin Engineering GmbH M3776UK-05/10...
  • Page 13: Programming Controller

    Slave cylinder retracted - T13 approx. 2-3 Slave cylinder Slave cylinder extended - T03 Slave cylinder extended Pressure has been achieved Hold pressure for approx. 3 s Pressure switch Fill pressure reservoir AUTOMATIC (external)/ Time Figure 5: Programme sequence © Martin Engineering GmbH M3776UK-05/10...
  • Page 14: Controller Operator Device

    Press the down arrow keys until the „PARAMETER“ menu entry is marked. Figure 7: Selection of the parameter Press (OK) to call up the parameter. Mark the desired parameter using the down arrow key. Figure 8: Changing parameter © Martin Engineering GmbH M3776UK-05/10...
  • Page 15 Press (OK) to change the password. Use the down or up arrow keys to choose a new numeric character. Use the right or left arrow keys to choose between the numeric cha- racters. © Martin Engineering GmbH M3776UK-05/10...
  • Page 16 11. Select the „ACTIVATE PASSWORD“ menu item in the following menu. 12. The system now automatically switches back to operating mode. NOTE Please also observe the corresponding chapter of the operating instructions of the controller regarding further options and settings of the password. © Martin Engineering GmbH M3776UK-05/10...
  • Page 17: Operation Of The Controller

    • Please follow all in-house regulations that were set up for the discharge of air cannons. • Let your behaviour ensure that no unauthorised persons have the possibility of discharging the air cannons. © Martin Engineering GmbH M3776UK-05/10...
  • Page 18: Discharging Ports

    Make sure that the operating mode selector switch (2) and the port selector switch (3) are set at zero before putting the system into operation. Otherwise there is ® a possibility of an uncontrolled discharge of the MARTIN MultiPort air cannon. IMPORTANT The operating mode „MAN“...
  • Page 19 Provided that the operating mode selector switch (2) is still set to „MAN“ after completion of the described sequence, the tank is refilled ® automatically and the MARTIN MultiPort air cannon discharges time and again in an endless loop into the selected port. To terminate the selected sequence, the operating mode selector switch (2) must be set to „0“.
  • Page 20 IMPORTANT In the event of malfunctions, the red signal lamp (5) „FAULT“ comes on both in automatic and in manual mode and the entire system switches to malfunction. © Martin Engineering GmbH M3776UK-05/10...
  • Page 21: Part Numbers

    • Memory card for EASY controller - parts no. 41468-MC-XXXX - Memory card with installed circuit diagram program to extend or reduce the number of ports and pressure reservoirs. • Spare key for manual/automatic mode switch - parts no.: 41294- KEY01 © Martin Engineering GmbH M3776UK-05/10...
  • Page 22: Parts List

    7 8 9 10 10 11 11 12 12 20 20 20 20 P 21 21 22 22 P 23 23 24 24P 25 25 26 26 27 27 P 28 28 29 29 P ® Figure 10: MARTIN MultiPort air cannon controller © Martin Engineering GmbH M3776UK-05/10...
  • Page 23: Part Number Explanation

    MultiPort air cannon controller Part number explanation MARTIN ® MultiPort controller Part No.: 41530 - X X Assembly part number Options firing sequence Z = Chronological firing sequence P = Programmable firing sequence Number of ports 1-8 © Martin Engineering GmbH M3776UK-05/10...
  • Page 24: Terminal Connections Diagram

    230V / 16A (2,5 mm²) - 3x 2,5 mm² (Power connection) Connecting cable from the solenoid valve cabinet Pressure switch - 3x 1,0 mm² External on (optional) - 2x 1,0 mm² Fault message for control room (optional) 3/4x 1,5 mm² Figure 11: Terminal connections diagram © Martin Engineering GmbH M3776UK-05/10...
  • Page 25 © Martin Engineering GmbH M3776UK-05/10...
  • Page 26: Eu Manufacturer´s Declaration

    EU Manufacturer´s declaration The EU Manufacturer’s Declaration or the CE Declaration of Conformity respectively for the MARTIN ® MultiPort Air Cannon Controller follows below. © Martin Engineering GmbH M3776UK-05/10...
  • Page 27 The initial operation of these machine components is prohibited until it has been determined that the system into which they are to be installed, complies with the provisions of the EU Directive version (2006/42/EC). Date: 05.01.2010 Manufacturer - Signature: Managing Director, Michael Hengl © Martin Engineering GmbH M3776UK-05/10...
  • Page 28 We Make Your Bulk Material Handling Cleaner, Safer and More Productive MARTIN ENGINEERING GMBH Headquarter Europe In der Rehbach 14 65396 Walluf, Germany Phone 0049 (0)6123 97820 Fax 0049 (0)6123 75533 Form no. M3776UK-05/10 E-Mail: info@martin-eng.de ©MARTIN ENGINEERING 2008 www.martin-eng.de...

Table of Contents