„Intended use“. Entitlement to damages is generally excluded, unless wilful intent or gross negligence on the part of Martin Engineering GmbH is proven, or if promi- sed product features are missing. We are not responsible for the possible consequences if the product is used in environments for which it is not sui- table or which do not comply with the technical standard.
Page 4
In the event that malfunctions and/or technical problems occur, please speak to the service department at Martin Engineering GmbH. We guaran- tee to implement suitable measures immediately. The guarantee provisions of Martin Engineering GmbH apply; we will gladly send these to you on request. 1.1.4...
Safety instructions, safety at work These operating instructions must be read through in full before starting ® work on the MARTIN MultiPort Controller. The operator must ensure that all assembly, inspection and maintenance work is carried out by authorised and qualified members of staff who have kept themselves adequately informed by thoroughly studying the operating instructions.
Description of the product General description ® The MARTIN MultiPort Air Cannon Controller, hereinafter referred to as controller, serve to control a maximum of one MARTIN ® MultiPort Air ® Cannon. The work cycle of the MARTIN MultiPort Air Cannon can either be triggered by a programmable time control, an external impulse or manu- ally.
The serial and model numbers are stated on the type plate which is attached to the upper right of the switch cabinet. Please state these numbers when ordering spare parts at Martin Engineering or an authorised dealer, as well as in all correspondence.
• MARTIN ® MultiPort Air Cannon Controller • possibly additional parts according to the order. If anything is missing contact Martin Engineering or the relevant rep- resentative. WARNING Before installing, turn off energy source to air cannon and all air cannon accessories.
Figure 3: Dimensions of the controller NOTE ® Mounting at a different location than directly to the MARTIN MultiPort air cannon is not envisaged. If you want to install the control system at a different location, please observe the mass stated in fig. 3 and all valid standards and regulations with regard to the installation and use of electrical equipment.
Make sure that the operating mode selector switch (2) and the port selector switch (3) are set at zero before putting the system into operation. Otherwise there is ® a possibility of an uncontrolled discharge of the MARTIN MultiPort air cannon. IMPORTANT The operating mode „MAN“...
Page 19
Provided that the operating mode selector switch (2) is still set to „MAN“ after completion of the described sequence, the tank is refilled ® automatically and the MARTIN MultiPort air cannon discharges time and again in an endless loop into the selected port. To terminate the selected sequence, the operating mode selector switch (2) must be set to „0“.