1.
Set the main switch (4) to „ON". In the starting position the master cy-
linder and the slave cylinder extend. Consequently the system is
closed. The white signal lamp (7) „RUN" comes on and indicates the
operational readiness of the system.
2.
Select the required port on the port selector switch (3).
3.
Set the operating mode selector switch (2) to „MAN".
4.
The pressure reservoir is filled automatically up to the set pressure.
After reaching the pressure, the orange signal lamp (6) „AIR TANK
FULL" comes on. The system is „ready to shoot".
5.
After a programmed period of time the master cylinder is retracted
and firing takes place at the selected port.
6.
After the firing has been carried out all cylinders return into the star-
ting position again after a programmed period of time.
Provided that the operating mode selector switch (2) is still set to
„MAN" after completion of the described sequence, the tank is refilled
automatically and the MARTIN
time and again in an endless loop into the selected port. To terminate
the selected sequence, the operating mode selector switch (2) must be
Automatic discharge
1.
Set the main switch (4) to „ON". In the starting position the master cy-
linder and the slave cylinder extend. Consequently the system is
closed. Make sure that the port selector switch (3) is set to position 0
and no port has been selected. The white signal lamp (7) „RUN" co-
mes on and indicates the operational readiness of the system.
2.
Set the operating mode selector switch (2) to „AUTO". The green si-
gnal lamp (1) „AUTOMATIC" comes on and indicates that the sys-
tem is in automatic mode.
3.
After expiry of a prescribed lead time, the programming runs indepen-
dently in accordance with the following schedule:
a.
Filling of the tank to the prescribed pressure. Filling times are
governed by the air inflow and set pressure.
b.
Once the pressure has been reached, the orange signal lamp (6)
„AIR TANK FULL" on the switch cabinet comes on, thus the
system is „ready to shoot".
c.
A slave cylinder is retracted in accordance with the prescribed
programming and order.
d.
Once the slave cylinder has reached its final position, the
master cylinder is retracted and the firing takes place. The
green lamp (6) „AIR TANK FULL" on the switch cabinet goes
out.
e.
After a one second waiting time, the master and the slave
cylinder return into the starting position again.
f.
After expiry of a prescribed time, the pressure reservoir is
NOTE
®
MultiPort air cannon discharges
set to „0".