DMP Electronics SecuraHub Series Installation And Programming Manual

Advertisement

Quick Links

INSTALLATION AND PROGRAMMING GUIDE
SecuraHub™SERIES PANELS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SecuraHub Series and is the answer not in the manual?

Questions and answers

Summary of Contents for DMP Electronics SecuraHub Series

  • Page 1 INSTALLATION AND PROGRAMMING GUIDE SecuraHub™SERIES PANELS...
  • Page 2 MODEL SecuraHub™ SERIES INSTALLATION AND PROGRAMMING GUIDE FCC NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Panel Specifications Power Supply ......................1 Communication ...................... 1 Keypads ......................... 1 Number of Zones ....................1 1.5 Enclosure Specifications ..................1 Introduction 2.1 System Configurations .................... 1 Caution Notes ......................1 Compliance Instructions ..................1 System Components Accessory Devices ....................2 Installation Location Information ....................
  • Page 4 TABLE OF CONTENTS 17.10 Zone Name ......................11 17.11 Zone Type ......................11 17.12 Area Assignment ....................11 17.13 Serial Number Entry ....................11 17.14 Stop ........................11 Listed Compliance Specifications 18.1 Introduction ......................12 18.2 Use Marking ......................12 18.2 Locations and Wiring .....................12 18.3 NFPA 72 .......................12 18.4 Types Of Service ....................12 18.5 Police Station Phone Numbers ................12 18.6...
  • Page 5: Panel Specifications

    INTRODUCTION & PANEL SPECIFICATIONS Panel Specifications Power Supply 12 VDC plug-in DC power supply Input: 120 VAC, 60 Hz .2A Output: 12 VDC .5A Standby Battery: DMP 3.8 VDC Lithium, 800 mAh Optional Standby Battery DMP 3.8 VDC Lithium, 3500 mAh All circuits inherent power limited Communication Optional 263LTE-V-GW cellular module to send messages to DMP Model SCS-1R or SCS-VR Central Station...
  • Page 6: System Components

    SYSTEM COMPONENTS System Components Accessory Devices Cellular Communicator Cards 265LTE-V-GW Cellular Communicator Allows you to connect the SecuraHub to any compatible Verizon LTE network. SecuraTouch™ Keypads 9862USB Keypad with Deskstand A 5” wireless touchscreen display with deskstand. Interactive shield for quick arming/disarming with a carousel menu.
  • Page 7 SYSTEM COMPONENTS Communicators ICOMSLZ-SCA Universal Network With this simple network communication add-on, you can upgrade almost any panel Communicator with Z-Wave to take advantage of remote-system management and control features. Program your own account number to easily work around existing installed systems. CELLCOMZ-LTE-V Universal Cell With this simple cellular communication add-on, you can upgrade almost any panel Communicator with Z-Wave...
  • Page 8: Installation

    INSTALLATION Installation Location Information Select a location that is centrally located between the wireless sensors used in the installation. Place the SecuraHub™ away from metal objects. Placing the panel on or near metal surfaces impairs performance. When selecting the proper mounting location of a transmitter, refer to the LED Survey Operation section of the specific installation guide for the transmitter being installed.
  • Page 9: Replacement

    INSTALLATION Replacement Use the following steps to replace the SecuraHub™ standby battery. Replacing the battery every 3 years under normal use is recommended. 1. Unplug the BAT battery connector from the SecuraHub™ panel. See Figure 2. 2. Remove and properly dispose of the used battery. Caution: Risk of fire, explosion, and burns.
  • Page 10: Prog Programming Connection

    INSTALLATION PROG Programming Connection Description Onsite programming can be completed using an associated wireless keypad or by connecting a hardwired keypad to the PROG header. On-Board Wireless 10.1 Wireless Antenna The SecuraHub™ wireless antenna is integrated into the circuit board. The panel’s built-in wireless receiver operates with Secura™...
  • Page 11: Cellular Connection

    INSTALLATION Cellular Connection 15.1 Description The CELL MODULE header is provided to connect a 265LTE-V-GW Cellular Communicator. The 265LTE-V-GW provides a fully supervised alarm communication path over the Verizon LTE network. Refer to the 265LTE-V-GW Cellular Installation Guide (LT-1703-GW) for complete installation information. Installing the 265LTE-V-GW the SecuraHub Caution: Touch grounded metal to discharge static before handling the SecuraHub PCB.
  • Page 12: Before You Begin

    PROGRAMMING INTRODUCTION Programming Introduction 16.1 Before You Begin Before starting to program, we recommend you read through the contents of this manual. The information in this document allows you to quickly learn the fast programming options and operational capabilities of the SecuraHub™...
  • Page 13: Keypad

    PROGRAMMING INTRODUCTION 16.3 Keypad Associate up to four SecuraTouch™ keypads to the SecuraHub™ panel. Their operation is shown and described in the following sections. STATUS POWER/ARMED PROXIMITY ICON CARD READER Panic Chime CAROUSEL MENU CURRENT Reset NAVIGATION LOCAL ARROWS DISARMED Favorites 98 77 WEATHER...
  • Page 14: Enter Characters - Standard Dmp Keypad

    PROGRAMMING INTRODUCTION 16.4 Enter Characters - Standard DMP Keypad Select Key or Area Number Key 1. Choose a character from the table. 2. Identify the Number Key the character correlates with and press it on the keypad. 3. Identify the Select Key or Area for that character and press that select key or area on the keypad.
  • Page 15: Fast Programming

    FAST PROGRAMMING Fast Programming 17.1 Fast Program FAST PROGRAM The Fast Program section allows you to quickly configure the essential settings for the SecuraHub™ panel. When the panel programming defaults are acceptable for installation and only basic programming options are needed, FAST PROGRAM allows the installer to quickly enter information without navigating all of the programming menus.
  • Page 16 COMPLIANCE Listed Compliance Specifications 18.1 Introduction The programming and installation specifications contained in this section must be completed when installing the SecuraHub™ in accordance with any of the ANSI/UL or SIA burglary standards. Additional specifications may be required by a particular standard. 18.2 Use Marking Household Burglar and Fire Control Unit.
  • Page 17 COMPLIANCE Household Burglar-Alarm System Units ANSI/UL 1023 19.1 Bell Cutoff The bell cutoff time cannot be less than 4 minutes. 19.2 Entry Delay The maximum entry delay used must not be more than 45 seconds. 19.3 Exit Delay The maximum exit delay used must not be more than 60 seconds. 19.4 Wireless External Contact When used, the External Contact of 1101, 1102, or 1106 transmitters must be programmed Normally Closed.
  • Page 18 COMPLIANCE Emergency Evacuation Plans 21.1 Overview The National Fire Protection Association recommends that you establish an emergency evacuation plan to safeguard lives in the event of a fire or other emergency. Draw a floor plan of your home or business On a clean sheet of paper, draw the walls, windows, doors, and stairs.
  • Page 19 COMPLIANCE False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010 22.1 Shipping Defaults and Recommended Programming SIA CP-01 FEATURE PROGRAMMING SHIPPING RECOMMENDED PARAGRAPH # AND REQUIREMENT RANGE GUIDE SECTION # DEFAULT PROGRAMMING* DESCRIPTION Required 4.2.2.1 Exit Time 19.3 Exit Delay 45 sec. - 250 sec. 60 Seconds (Programmable) Seconds...
  • Page 20 REVISIONS Revisions to This Document This section explains the changes made to this document during this revision. It lists the date and identifies the change(s) made, the related section number and section heading, and a summary of the change. Ver. Section Number and Heading Quick Explanation of Changes 1.01...
  • Page 21 Digital Monitoring Products SecuraHub Installation and Programming Guide...
  • Page 22 Certifications Ordering Information SecuraHubW 900MHz with Wi-Fi FCC Wireless Receiver AND Z-Wave Approvals SecuraHubZ 900MHz with Z-Wave FCC ID: CCKPC0181 SecuraHubWZ 900MHz with Wi-Fi and Z-Wave IC: 5251A-PC0181 Accessories FCC Wi-Fi Network Approvals 265LTE-V-GW LTE Cellular Communicator FCC ID: VW4-ATWINC1500 XTL+BAT800/8 3.8VDC Nominal Lithium, 800mAh Battery XTL+BAT3500/8 3.8VDC Nominal Lithium, 3500mAh Battery...

Table of Contents