Fault Table; Technical Data - Bosch Rexroth AGEV1-48404-AA/HM/L01H01-XC Operating Instructions Manual

Manifold block
Table of Contents

Advertisement

34/40

Technical data

Fault
External leakage
Bosch Rexroth AG, Manifold block type AGEV1-48404-AA/HM/L01H01-XC, RE 62272-B/03.19

14.2 Fault table

Manifold blocks are usually not sensitive to faults if the prescribed operating
conditions and hydraulic fluid quality are complied with.
Possible cause
Seals on connection face damaged
Other leakage
In the case of faults of individual components refer to the product description or
operating instructions of the components, see 16.1"List of addresses".
15 Technical data
Tabelle 8: Technical data
General
Installation orientation
Installation conditions
Admissible ambient temperature range
Storage temperature range
°C
Weight
kg
Surface protection
Hydraulic
Hydraulic fluid
Hydraulic fluid temperature range
Max. permissible degree of contamination of the
hydraulic fluid
Cleanliness class according to ISO 4406 (C)
Permissible pressures in ports
Tank port (AAHL, BAHL)
Leakage oil port (Y)
Pressure port (AAL, BAHL)
Pilot pressure (X1AL)
bar
Load pressure (piston side, measured at 1.03)
Load pressure (piston rod side, measured at
2.03)
Factory settings of valves when delivered
Pressure relief valve (2.04)
Counterbalance valve (1.02, 2.02)
Remedy
Remove the hydraulic component and replace
the seals.
Replace leaky hydraulic valves.
optional
Coasts and offshore with salt-laden air
°C -20...+50
-10...+50
160
CP7A DCCS92010, corresponds to C5M,
medium, in line with DIN EN ISO 12944-2
Technical specification:
AVIA Syntofluid PE-B 50
°C -20...+80
Class 19/17/14
bar 50
bar 20
bar 300
max. 120
1)
corresponds to 100 bar, max. 300 bar
bar
corresponds to 132 bar, max. 300 bar
bar
bar Setting 160 bar at the time of delivery
bar Customer setting on site, 50 bar at the time of
delivery

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents