Environmental Requirements; General Specifications - Brocade Communications Systems 300 Reference Manual

Table of Contents

Advertisement

TABLE 5
Specification
Input voltage
Input line frequency
BTU rating
Inrush current

Environmental requirements

Table 6
transportation or storage) conditions.
TABLE 6
Condition
Ambient Temperature
Humidity
Altitude
Shock
Vibration
Air flow
NOTE
The -10° to 40° Celsius range applies to the ambient air temperature at the air intake vents on the
non-port side of the switch. The temperature inside the switch can be up to 80° Celsius during
switch operation.
If the internal temperature range exceeds the operating ranges of the components, the LEDs, error
messages, and Fabric Watch alerts indicate a problem. Enter the tempShow or Fabric Watch
commands to view temperature status.

General specifications

Table 7
TABLE 7
Specification
Autoconfiguring port types
System architecture
System processor
Brocade 300 Hardware Reference Manual
53-1000862-02
Brocade 300 Power Supply Specifications (Continued)
lists the acceptable environment for both operating and nonoperating (such as during

Environmental Requirements

Acceptable Range During Operation
-10° to +40° C (14° to 104° F)
10% to 85% RH noncondensing, at 40
with maximum gradient of 10% per hour
0 to 3 km (9,842 ft) above sea level
20 G, 6 ms duration, half sine wave
0.5 G, 5-500 Hz
High speed: 39.1 CMH (23 CFM)
Low speed: 30.6 CMH (18 CFM)
lists the system specifications for the Brocade 300.

General Specifications

Environmental requirements
Value
85 - 264 VAC, universal
47 - 63 Hz
277 BTU/hr
21.5 Amps at 240 Vac Cold Start
°
C,
Description
F_Port, FL_Port, M_Port, N_Port, and E_Port
Nonblocking shared-memory switch
Power PC 440EPx,667 MHz CPU
Acceptable Range During Non-Operation
°
°
°
°
-25
to 70
C (-13
to 158
F)
10% to 90% RH noncondensing, at
70° C
0 to 12 km (39,370 ft) above sea
level
33 G, 11 ms duration, half sine
2.0 G,
5-500 Hz
None required
A