Brocade Communications Systems BROCADE 4424 BLADE SERVER 53-1000571-01 Hardware Reference Manual
Brocade Communications Systems BROCADE 4424 BLADE SERVER 53-1000571-01 Hardware Reference Manual

Brocade Communications Systems BROCADE 4424 BLADE SERVER 53-1000571-01 Hardware Reference Manual

San i/o module
Table of Contents

Advertisement

Quick Links

53-1000571-01
53-1000571-01
November 2007
Brocade 4424 Blade Server
SAN I/O Module
Hardware Reference Manual

Advertisement

Table of Contents
loading

Summary of Contents for Brocade Communications Systems BROCADE 4424 BLADE SERVER 53-1000571-01

  • Page 1 53-1000571-01 53-1000571-01 November 2007 Brocade 4424 Blade Server SAN I/O Module Hardware Reference Manual...
  • Page 2: Document History

    Export of technical data contained in this document may require an export license from the United States government. The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
  • Page 3: Table Of Contents

    Chapter 1 Chapter 2 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-1000571-01 Rev. A How this document is organized ......v Supported hardware and software .
  • Page 4 Regulatory certifications ....... 33 4424 Blade Server SAN I/O Module Hardware Reference Manual...
  • Page 5: About This Document

    This document is a hardware reference manual, written for SAN administrators who are using any Blade Server that supports the Brocade 4424 Blade Server Fibre Channel SAN I/O Module. It provides the information needed to understand the installation, configuration, and maintenance of the Brocade 4424 SAN I/O Module.
  • Page 6: Document Conventions

    Identifies keywords and operands Identifies text to enter at the GUI or CLI Provides emphasis Identifies variables Identifies paths and Internet addresses Identifies document titles Identifies CLI output Identifies syntax examples 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 7: Additional Information

    Web Tools Administrator’s Guide • Fabric Watch Administrator’s Guide Brocade 4424 Blade Server Fibre Channel SAN I/O Module • Brocade 4424 Blade Server Fibre Channel SAN I/O Module Hardware Reference Manual (this document). • Brocade 4424 QuickStart Guide. • Brocade release notes for Fabric OS version supported by the Brocade 4424.
  • Page 8: Getting Technical Help

    SAN I/O Module model • SAN I/O Module operating system version • Error numbers and messages received • supportSave command output • Detailed description of the problem and specific questions viii 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 9: Document Feedback

    Forward your feedback to: documentation@brocade.com Provide the title and version number and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement. 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 10 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 11: Chapter 1 Introducing The San I/O Module

    The Brocade 4424 is a 24-port Fibre Channel module with 8 external ports and 16 internal ports designed for installation in a Dell PowerEdge M1000e Blade Server Enclosure. The product ships with 12 ports enabled and can be upgraded to 24 ports through Ports on Demand (POD) licensing.
  • Page 12: Features

    One serial console port on the front panel (RJ45 connector). • The following light-emitting diodes (LEDs) for each external port. One green/amber LED to indicate status for each port. One green/amber LED to indicate link speed for each port. 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 13: Access Gateway Mode

    The remaining 10 licenses are assigned to active ports as required. Once licenses are issued, they can be moved from one port to another, making port licensing more flexible. 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 on page 22 for details about the SAN I/O Module LEDs.
  • Page 14: Hardware Description

    Port side Externally accessible ports and LEDs are on the port side of the SAN I/O Module. The port side faces out when the SAN I/O Module is inserted into the I/O bay of the Blade Server enclosure. Figure 1 details the port side.
  • Page 15: Nonport Side

    SAN I/O Module as it will seat correctly when the insertion arm is closed. When the SAN I/O Module is inserted, the backplane connectors activate a connection port, allowing the SAN I/O Module to be configured in the Blade Server Enclosure. FIGURE 3 Nonport Side, Viewed from Top 1.
  • Page 16: Labeling

    The external ports can form 2-port trunks, 3-port trunks, or a 4-port trunk. For details about Brocade ISL Trunking, see the Brocade Fabric OS Procedures Guide. on page 23 provides details about removing SFPs and follow the links to the latest compatibility matrix. From the 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 17: Optional Features

    Unpacking and installing the SAN I/O Module If the SAN I/O Module is installed in the Blade Server Enclosure that is shipped to you, skip this section. This section applies when installing a new module in an empty bay or replacing an existing SAN I/O Module.
  • Page 18: Cabling Guidelines

    Access Gateway or Full Fabric Switch mode. 8. For complete instructions to install the SAN I/O Module into the Blade Server Enclosure, refer to the section on installing an I/O module in the Blade Server Enclosure Hardware Owner’s Manual.
  • Page 19: Chapter 2 Configuring The San I/O Module

    The following items are required for configuring and connecting the SAN I/O Module for use in a network and fabric: • The SAN I/O Module installed in a Blade Server Enclosure. For instructions, refer to the steps on installing an I/O module in the Hardware Owner’s Manual for the Blade Server Enclosure. •...
  • Page 20: Modify The San I/O Module Ip Address

    Ethernet network requirements. NOTE It is recommended that you set the IP address using the Blade Server Enclosure CMC GUI application because this enables centralized management of the SAN I/O Module. Using the SAN I/O Module CLI to set the IP address Use the following tasks to change the IP address on the SAN I/O Module using the Module’s CLI.
  • Page 21: Using The Cmc Cli To Set The Ip Address

    2. At the command prompt, type connect switch-x where x is the bay where the SAN I/O Module is installed. For example, switch-x can be: 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 Modify the SAN I/O Module IP address...
  • Page 22: Using The Cmc Gui To Set The Ip Address

    Apply. 3. To enable DHCP, select DHCP Enabled and click Apply. FIGURE 4 CMC Setup Tab NOTE Refer to the documentation for the CMC GUI application for additional detail. 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 23: Connecting The San I/O Module To The Ethernet Network

    Fabric parameters (yes, y, no, n): [no] y Domain: (1..239) [1] 155 R_A_TOV: (4000..120000) [10000] 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 Connecting the SAN I/O Module to the Ethernet network on page 8 before beginning the following procedure.
  • Page 24 A cable should not be bent to a radius less than 5.08 cm (2 inches) under full tensile load and 3.048 cm (1.2 inches) with no tensile load. (yes, y, no, n): [no] 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 25: Changing From Fabric Switch Mode To Access Gateway Mode

    8. Verify the correct operation of the SAN I/O Module in the fabric by typing the fabricShow CLI command from the workstation. 9. Back up the SAN I/O Module configuration to an FTP server by typing the configUpload command and following the prompts.
  • Page 26: Command Line Interface

    This command is optional and is only required if you are converting an existing SAN I/O Module to Access Gateway mode. configUpload Save 4. Enter the following command to enable Access Gateway mode: ag ––modeEnable 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 27: Changing From Access Gateway Mode To Fabric Switch Mode

    SAN I/O Module operation, or alternatively, you can disable and re-enable the SAN I/O Module to activate all ports. If you remove a POD License, ports that were enabled by that license are disabled. 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 Changing from Access Gateway Mode to Fabric Switch Mode...
  • Page 28: Activating Ports With A Pod License

    2. Enter the IP address of the SAN I/O Module in the address field and press Enter. For more information about using Web Tools, see the Web Tools Administrator’s Guide. 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 29: Chapter 3 Operating The San I/O Module

    N_Ports, NL_Ports, and E_Ports as well as host adapters, Redundant Array of Independent Disks (RAID) storage devices, hubs, Fibre-SCSI bridge devices, and older switch families. 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 • soft WWN zoning •...
  • Page 30: Operating System Support

    Using the Fabric Access interface to the Fabric OS, a client application can retrieve information and modify the configuration of Brocade switches in the fabric. Version 8, 9, 10 AS 3.0, AS 4.0 Version 9, 10 ES 3.0, ES 4.0 9.2, 9.3 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 31: Interpreting Post Results

    Fabric OS Administrator’s Guide or the Web Tools Administrator’s Guide. 2. Use the Blade Server Enclosure’s Chassis Management Controller (CMC) GUI to verify that the SAN I/O Module is working correctly.
  • Page 32: Interpreting Led Activity

    Both off (dark): 1 Gbit/sec FC module green/amber Off: status SAN I/O Module is off or power supplies for the Blade Server or onboard DCC have failed. Green: No errors and all ports are ready for use. Amber: Steady: Boot-up state, port(s) offline, or in reset state.
  • Page 33: Locating The Serial Number

    Before beginning this procedure, ensure that you have a replacement SAN I/O Module or filler panel available because you do not want to leave the slot on the Blade Server Enclosure open for an extended period of time. The slot must be filled with either a replacement SAN I/O Module or a filler panel to maintain proper airflow.
  • Page 34 Cable Release Bale 5. Refer to the Hardware Owner’s Manual for the Blade Server Enclosure to remove and replace the SAN I/O module from the enclosure. ATTENTION If you are not replacing the SAN I/O Module, use a filler panel to fill the empty slot to maintain proper air flow.
  • Page 35: Access Gateway Mode Default Port Mapping

    Memory Specifications Memory Type PowerPC 440GP processor SDRAM Boot flash Compact flash 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 Value 333 MHz 256 MB - for system memory at 64 bits wide with 8 ECC bits 4 MB...
  • Page 36: Weight And Physical Dimensions

    Random: 0.5G at 5-500 Hz for 60 minutes 86 °F (30°C) Ambient: Approx. 3CFM 104°F (40°C) Ambient: Approx. 9CFM 4424 Blade Server SAN I/O Module Hardware Reference Manual Non-operating -45.4°F to 163.4°F (-43°C to 73°C) 5% to 95%, non-condensing at 100.4 °F (38°C)
  • Page 37: Architectural Specification

    The SAN I/O Module switch meets or exceeds the Fibre Channel standards for compliance, performance, and feature capabilities as defined in the Brocade standards compliance list. This information is available at: http://www.brocade.com/products/interop/standards_compliance.jsp 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 Architectural specification Table...
  • Page 38: Regulatory Compliance

    Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance might arise. When such trouble occurs, the user might be required to take corrective actions. 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 39: Bsmi Statement (Republic Of Taiwan)

    Regulatory compliance BSMI statement (Republic of Taiwan) 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 40: Ce Statement

    Standards, 21 CFR Subchapter I and the international laser safety standard IEC 825-2. CAUTION Use only optical transceivers that are qualified by Brocade Communications Systems, Inc. and comply with the FDA Class 1 radiation performance requirements defined in 21 CFR Subchapter I, and with IEC 825-2.
  • Page 41: Environmental Regulation Compliance

    The EPUP assumes that the product will be used under normal conditions in accordance with the operating manual of the product. EPUP ocade EPUP 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 Environmental regulation compliance (EPUP) Brocade Brocade...
  • Page 42 O indicates that no such substances are used or that the concentration is within the aforementioned limits. Hazardous/Toxic Substance/Elements Lead (PB) Mercury Cadium Hexavalent (Hg) (CD) Chromium (CR6+) 4424 Blade Server SAN I/O Module Hardware Reference Manual Polybrominated Polybrominated Biphenyl (PBB) Diphenyl Ether (PBDE) 53-0000571-01...
  • Page 43: Regulatory Certifications

    (NEMKO CB Report) (Norway only) Slovakia, Slovenia, Spain, Sweden, The Netherlands, and United Kingdom) International IEC 60950+A1+A2+A3+A4+A11 Japan IEC 60950+A1+A2+A3+A4+A11 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 CHINA ROHS << >> Environmental regulation compliance (HS/TS) (HS) CR6+...
  • Page 44 KN24 KN22 GOST R 51318.22-99 (Class A) GOST R 51318.24-99 GOST R 51317.3.2-99 GOST R 51317.3.3-99 CNS13438 EN55022 Class A FCC Part 15, Subpart B (CFR title 47), Class A 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 45 15 ipAddrSet 11 licenseshow 2, 17 switchDisable 13, 16 switchShow 15, 21 compact flash 25 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 compatibility matrix 6 configUpload command 15, 16 configure command 13 connect command 11 connect switch-x command 11...
  • Page 46 23 SFPs 2, 6 shipping package 7 shock 26 specifications 26 supported HBAs 27 supported SFP 6 switchDisable command 13, 16 switchShow command 15, 21 SWL 2, 6 temperature 26 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 47 SAN I/O Module 7 VCCI statement 28 vibration 26 web browser 18 Web Tools 7, 18 using to connect SAN I/O Module 18 weight 26 zoning 2, 7, 20 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...
  • Page 48 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01...

This manual is also suitable for:

Poweredge m420Poweredge m5204424

Table of Contents