Before closing door test for cylinder function of lock cylinder
and Inside lever:
a. Insert key into cylinder and rotate.
b. The key will retract the latch. Key should rotate freely.
c. Inside lever retracts latch.
d. Close door, ensure latch fully extends into strike
and does not bind.
NOTE: Ensure LED operates as configured*:
LED remains green when panel asserts GREEN_LED signal
*For configurations with GREEN_LED override enabled (Alternate Indicator Configuration);
see Application Diagram #2 in Section 6.
Note: Once electrical wiring has been successfully
completed according to proper application, perform
the following:
a. Turn power ON.
b. Verify reader LED is ON
(Red or Green depending on reader configuration;
see reader LED Configuration).
c. Present proximity credential and verify LED and
sounder activity.
d. Verify valid card read at EAC Panel.
e. Verify system operation functions; i.e., the door unlocks
when a valid credential is presented to the reader.
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field*. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product's features and capabilities.
*For directions on use, see operating
instructions provided with unit.
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

8) Operational Check

21
Feature
12 or 24VDC solenoid lock
voltage adjustable
Operates as Fail Safe or Fail
Secure
"Learn" mode allows testing
of specific cards without pro-
gramming at panel level
Card reader data integrity is
validated at test unit
Displays detailed Wiegand
data, including hexadecimal
string and total bits received
Displays measured end-of-line
resistor values (if applicable)