Sharp LC-R60HDU Service Manual page 24

Lcd high-definition rear projector
Table of Contents

Advertisement

LC-R60HDU
Adjusting the counter voltage and chromaticity, and creating the γ data
Take the following procedures after the LCD panel has been replaced and the convergence readjusted.
Chromaticity adjustment and γ data program diagram
Universal Programmer
MODEL 1881
Printer cable connected
D-sub 25pin
Mebius VGAmode
CL100
measuring probe
CL100
Light quantity
correction
polarizer
Extension
cable
MA-1
Specific cable
connected to LCD
drive PWB (LA connector)
CL100 setup jig
24
Output PWB
Optical
mechanism
Light quantity
adjustment polarizer
Projection lens
LCR60HDU