Definitions
All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except
Master)
PIN
code access. When attempting to enter a code while the unit is in Lockout, the keypad flashes 8 times
and the lock beeps 3 times as well.
Audio Mode:
Choosing
Disable (3)
areas. Audio mode is enabled or disabled through feature programming by the Master code.
Automatic Re-lock Time: After a successful unlock, the unit will re-lock automatically after duration selected in the
Advanced Lock Settings (Main Menu selection #3).
Handing the Lock: Lock handing refers to which direction the bolt comes out of the door (right or left). If the lock
was programmed off the door, the lock may need adjusting. Review the Re-Handing instructions listed in Hardware
Troubleshooting.
Inside Indicator Light: Located on the interior lock. Shows active status (Locked) of lock and can be enabled or
Advanced Lock Settings
disabled in the
Low Battery: When battery power is low, the Status Indicator flashes
the cylinder key override.
Master
PIN
Code:
The Master
to programming the lock. The Master code will also operate (unlock/lock) the lock.
Network Module Setting: With the optional Network Module installed, this setting becomes available thru the Main
Menu (7) and allows the lock to connect with a network controller.
One Touch Locking: When the latch is retracted, activating the keypad will extend the latch(during Automatic Re-
lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is
PIN code will re-lock the lock.
Privacy Mode: Privacy mode is disabled by default. Enable Privacy mode by pressing the privacy button for 4
seconds to put the lock in do-not-disturb mode (all pin codes are disabled).
Shutdown Time: The unit will shut down (flashing keypad) for sixty (60) seconds and not allow operation after the
wrong code entry limit has been met.
Tamper Alert: Audible alarm sounds if attempting to forcibly remove outside lock from door.
User
PIN
Code:
The user code operates the lock. The maximum number of user codes with Z-Wave Plus or Zigbee
network module is 250; without network module or with iM1 network module, maximum is 25; with Bluetooth,
maximum is 12.
Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid
and not allow operation for sixty (60) seconds.
in Audio mode shuts off the code confirmation tone play-back for use in quiet
(Main Menu selection #3).
PIN
code is used for programming and for feature settings.
P/N
YRL EMICL PBINSTL FUL
-
-
RED
. If battery power is completely lost, use
PIN
33
-
Rev B
It must be created prior
not
in use
(disabled)
, any valid
code, the unit will shut down

Advertisement