ACS 653, ACS 663 Service Manual
Replacement Refrigerant Identifier
(if present)
WARNING: Disconnect the unit from
the power source before beginning
service work. Incorrect use or
connections can cause electrical
shock.
WARNING: Wear safety goggles
when working with refrigerants.
Refrigerants can cause eye injury.
WARNING: Use extreme caution
w h e n d i s c o n n e c t i n g h o s e s .
Pressurized refrigerant may be
present in hoses. Point hoses away
from you and anyone nearby.
1. Clear service hoses and remove them.
2. Switch off the machine.
3. Remove the 3 screws (1) either from left
and right side of the machine and the
2 screws (2) underneath the frontal panel
(see Figure 3-12).
4. Remove the front plastic cover.
5. Open the service rear door.
6. Remove the rear cover (above the service
door) by pushing it up and extract it by
pulling it out.
Robert Bosch GmbH
1
1
1
Figure 3-12. Front plastic cover removal
81
Electrical
SP00D00624
2021-04-08
2
2

Hide quick links: