Protective Devices; Door Switch; Ped Directive 2014/68/Eu; Machine Handling - Bosch ACS 653 Repair Instruction

Table of Contents

Advertisement

ACS 653, ACS 663 Service Manual
WARNING: Warranty is not valid in all cases of improper use of the machine and if the
machine is not submitted to periodic ordinary and extraordinary maintenance (according
to PED directive 2014/68/EU) provided in this original instructions. The manufacturer
therefore declines all responsibilities for any damage resulting from not observing all the
instructions and warnings provided to the user regarding installation, use and maintenance.

Protective devices

The machine is equipped with the following protective devices:
• Over pressure valves.
• A maximum pressure switch stops the compressor when excessive pressure is sensed.
WARNING: Tampering with these protective devices could result in serious injury.
WARNING: Do not modify the pressure relief valve or change the control system
settings. Using the machine in a manner for which it was not designed will compromise
the machine and nullify the protections provided.
CAUTION: Check always the pressure gauges values to ensure that pressures are
maintained within the limits specified in the "Unit specifications" section.

Door switch

Door switch on service rear door disconnects electrical power to the unit when opened.
WARNING: Do not tamper the interlock switch. During normal operation, the rear
service door must always be closed and the above panel in place.

PED directive 2014/68/EU

The machine includes parts subject to PED EU directive 2014/68/EU, Pressure Equipment
Directive. PED directive regulates all the pressurized part defining for them categories based on
volume-pressure ratio and based on fluid refrigerant type. Those parts then have not to be anyhow
modified nor removed. Under the responsibility of the owner, the machine and parts falling in
the scope of PED shall be checked either during commissioning and periodically fulfilling local
country regulations and norms. Parts in the scope of PED are:
• Tank.
• Pressure relieve valve.
• High pressure switch.
• Recovery group.
• Piping.
Call Bosch service center to get technical specifications for each part listed.

Machine handling

The unit should normally be moved on flat surfaces with a maximum slope of 15 ° and on the four
wheels, avoiding excessive shaking. When stopped then the brake on the front wheels must be
inserted. On slightly irregular surfaces, the unit can be moved by keeping it slightly inclined and
grounded on the two rear wheels by making sure to have a firm grip on the rear handle.
CAUTION: Although heavier components of the unit are installed on the bottom of
the unit in order to lower as much as possible the center of gravity, it's however not
completely removed the risk of overturning.
Robert Bosch GmbH
7
SP00D00624
2021-04-08