Table of Contents

Advertisement

Introduction

These units are designed to be compatible with existing service equipment and standard service
procedures. These machines utilize a single-pass system that meets specifications for recycled
refrigerant. Follow recommended service procedures for the containment of refrigerant.
Each unit includes a high-vacuum pump for fast, thorough evacuation. The compressor first pulls
the A/C system to -0.4 bar; the compressor then works with the vacuum pump to pull a vacuum
to an absolute pressure of less than 1.0 bar.
NOTE: Refrigerant systems require special oils. Refer to the A/C system manufacturer's service
manual for oil specifications.
1
12
11
10
9
8
1. Gauge low pressure (LP)
2. Printer (optional, standard on P variants)
3. Gauge high pressure (HP)
4. Identifier Filter (for ACS 663-RI only)
5. Master switch
6. Power supply socket
7. Circuit breaker
8. UV dye bottle
9. Fresh oil bottle 2 (POE)
10. Fresh oil bottle 1 (PAG)
11. Oil drain bottle
12. Display and control panel
SP00D00624
2021-04-08

Introduction

2
3
4
5
6
7
Figure 1-1. Description of machine
ACS 653, ACS 663 Service Manual
21
20
19
13. Flush port (high pressure*)
14. Flush port (low pressure*)
15. Service hose port (high pressure*)
16. Service hose port (low pressure*)
17. Contaminant recovery outlet port
(for ACS 663-RI only)
18. Front wheels with locking brake
19. Rear wheels
20. Hoses wraping support
21. 2 x USB 2.0 slot
(*) max 25 bar (2.5 MPa)
10
13
14
15
16
17
18
Robert Bosch GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs 653-pAcs 663Acs 663-pAcs 663-ri

Table of Contents