Lincoln Electric IDEALARC DC-1500 Service Manual page 93

Constant voltage and constant current dc arc welding power source, 3 phase rectifier type
Hide thumbs Also See for IDEALARC DC-1500:
Table of Contents

Advertisement

F-59
Testing is required after the removal of any mechanical part that could affect the machine's elec-
trical characteristics, or if any electrical components are repaired or replaced.
Input Volts/Phase/Hertz
460/3/60
575/3/60
Mode
Variable Voltage
Auxiliary Output (#31-#32)
MAXIMUM ACCEPTABLE OUTPUT VOLTAGE - AT MINIMUM OUTPUT
Mode
Constant Voltage Innershield
Variable Voltage
MINIMUM ACCEPTABLE OUTPUT VOLTAGE AT MAXIMUM OUTPUT
Mode
Variable Voltage
Constant Voltage Submerged Arc
TROUBLESHOOTING AND REPAIR
RETEST AFTER REPAIR
INPUT IDLE AMPS AND WATTS
Maximum Idle Amps
OPEN CIRCUIT VOLTAGES
Input Hertz
SETTINGS
Input Hertz
SETTINGS
IDEALARC® DC-1500
12.5
9.9
60
60
118/112 AC @ 5amp load
60
200 amps @ 20/17 VDC
60
200 amps @ 20/17 VDC
Input Hertz
60
1500 Amps @ 70/60 VDC
60
1500 Amps @ 64/60 VDC
Maximum Idle KW
3.84
3.84
Open Circuit Volts
101/97
Load
Load
F-59